12
Catalyst 6000 Family Network Analysis Module Installation and Configuration Note
78-10406-05
Installing and Removing the NAM
Step 3
If the desired slot is empty and is not covered by a switching-module filler plate, go to
Step 5
.
Otherwise, loosen the captive installation screws (with a screwdriver if necessary) that secure the
switching-module filler plate or the existing switching module in the desired slot.
Warning
Blank faceplates and cover panels serve three important functions: they prevent exposure to
hazardous voltages and currents inside the chassis; they contain electromagnetic interference
(EMI) that might disrupt other equipment; and they direct the flow of cooling air through the
chassis. Do not operate the system unless all cards, faceplates, front covers, and rear covers are
in place.
Step 4
Remove the switching-module filler plate or the existing switching module.
Step 5
Hold the NAM with one hand, and place your other hand under the carrier to support the module.
Caution
Do not touch the printed circuit boards or connector pins.
Step 6
Place the module in the slot.
Step 7
Align the notch on the sides of the switching-module carrier with the groove in the slot. (See
Figure 3
.)
Figure 3
Installing Modules in the Catalyst 6000 Family Switch
33087
FAN
LED
INPUT
OK
FAN
OK
OUTPUT
FAIL
o
INPUT
OK
FAN
OK
OUTPUT
FAIL
o
1
2
3
4
5
6
7
8
9
SUPERVISOR I
WS-X6K-SUP1
STATUS SYSTEMACTIVE PWR MGMT
RESET
CONSOLE
Switch Load
100%
1%
DTE/
DCE
PCMCIA
EJECT
PORT 1
LINK
PORT 2
LINK
SUPERVISOR I
WS-X6K-SUP1
STATUS SYSTEMACTIVE PWR MGMT
RESET
CONSOLE
Switch Load
100%
1%
DTE/
DCE
PCMCIA
EJECT
PORT 1
LINK
PORT 2
LINK
8 PORT GIGABIT ETHERNET
WS-X6408
1
LIN
K
STATUS
2
3
4
5
6
7
8
LIN
K
LIN
K
LI
N
K
LIN
K
LIN
K
LIN
K
LIN
K
8 PORT GIGABIT ETHERNET
WS-X6408
1
LIN
K
STATUS
2
3
4
5
6
7
8
LINK
LINK
LINK
LINK
LINK
LINK
LINK
8 PORT GIGABIT ETHERNET
WS-X6408
1
LIN
K
STATUS
2
3
4
5
6
7
8
LIN
K
LINK
LINK
LINK
LINK
LINK
LINK
24 PORT 100FX
WS-X6224
ST
AT
US
24 PORT 100FX
WS-X6224
24 PORT 100FX
WS-X6224
ST
AT
US
ST
AT
US
1
LIN
K
2
LIN
K
3
LIN
K
4
LIN
K
5
LIN
K
6
LI
N
K
7
LI
N
K
8
LIN
K
9
LIN
K
10
LIN
K
11
LIN
K
12
LIN
K
13
LIN
K
14
LI
N
K
15
LIN
K
16
LI
N
K
17
LIN
K
18
LIN
K
19
LIN
K
20
LIN
K
21
LIN
K
22
LI
N
K
23
LIN
K
24
LIN
K
1
LIN
K
2
LIN
K
3
LIN
K
4
LIN
K
5
LIN
K
6
LIN
K
7
LIN
K
8
LIN
K
9
LIN
K
10
LIN
K
11
LIN
K
12
LIN
K
13
LIN
K
14
LIN
K
15
LIN
K
16
LIN
K
17
LIN
K
18
LIN
K
19
LIN
K
20
LIN
K
21
LIN
K
22
LIN
K
23
LIN
K
24
LIN
K
1
LINK
2
LINK
3
LINK
4
LINK
5
LINK
6
LINK
7
LINK
8
LINK
9
LINK
10
LINK
11
LINK
12
LINK
13
LINK
14
LINK
15
LINK
16
LINK
17
LINK
18
LINK
19
LINK
20
LINK
21
LINK
22
LINK
23
LINK
24
LINK
ST
AT
US
1
0
PCMCIA
SLOT
EJECT
NTWK ANALYSIS HDL
MD
SHUTDOWN
For Vendor Use Only
WS-X6380-NAM