2-13
Cisco Media Gateway Controller Node Manager Installation Guide
OL-18332-04
Chapter 2 Installing Cisco MNM
Performing a New Installation of Cisco MNM
Follow the procedure below to install Cisco MNM on a standalone system or on both machines
(management server and presentation server) in a distributed configuration. The Cisco MNM installation
process automatically detects if the complete Cisco EMF software is installed, or only the Cisco EMF
client, and then it installs the correct Cisco MNM components.
Installing Cisco MNM
Step 1
Start Cisco EMF if it is not already running.
Step 2
Change the working directory using the following command:
%
cd <CEMF_ROOT>/bin
Step 3
Verify that Cisco EMF is running using the following command:
% .
/cemf query
Text similar to the following is displayed:
CEMF Manager 3.2 initialized
Step 4
Change to the root user using the following command:
#
su - root
Step 5
Verify that the Volume Management daemon is running using the following command:
#
ps -ef | grep vold
Text similar to the following is displayed:
root 483 1 0 Oct 23 ? 0:00 /usr/sbin/vold -f /etc/vold.conf
Note
If the daemon name is not displayed, start the daemon using the following command:
/etc/init.d/volmgt start
Verify that the Volume Management daemon is running with the command provided above. If it
is still not displayed, contact your system administrator.
Step 6
Insert the Cisco MNM CD in the CD-ROM drive.
Step 7
Enter the following command:
#
cd /cdrom/cscocmnm
Step 8
Enter the following command to start the installation:
#
./cmnminstall
Text similar to the following is displayed:
----------------------------------------------------------------------
Cisco MGC-Node Manager Installation
Wed Oct 29 07:57:35 PM
----------------------------------------------------------------------
Setup has detected that the CEMF Manager software is installed.
Do you wish to install the CSCOcmnm Manager software. [y/n]: