Optical Amplifier (EDFA) Modules
51
17.0/20.0/22.0
dBm
45.0
25.0
0
-10.0
Ok
Alarm
5.0
0.1
dBm
Broadcast EDFA - Constant Gain Mode
Product Type
Major
High
Minor
High
Minor
Low
Major
Low
Values
Typical
Value
Hysteresis
Units
17.0/20.0/22.0
dBm
45.0
25.0
-13.0
-15.0
Ok
Alarm
-12.0
0.1
dBm
Laser Temperature Set Point Adjustment
In an effort to reduce EDFA power consumption, laser temperature set point is
changed based on EDFA module temperature. Typically, the laser temperature set
point is set at 25°C. When module temperature is greater than 60°C and less than
10°C, laser temperature set point is adjusted.
Hot Condition (Module Temperature > 60° C)
For module temperature less than 60.0°C, laser set point temperature is set at 25°C.
For every degree of module temperature greater than 60°C, laser set point
temperature is also increased by that amount until module temperature reaches 70°C,
then laser temperature set point is fixed at 35°C. For example, if module temperature
is 64°C, laser set point temperature is 29°C. If module temperature is 85°C, laser set
point temperature is 35°C.
Cold Condition (Module Temperature < 10° C)
For module temperature greater than 10°C, laser set point temperature is set at 25°C.
For every degree of module temperature less than 10°C, laser set point temperature
is also decreased by that amount until the module temperature reaches -5°C, then
laser temperature set point is fixed at 10°C. For example, if module temperature is
-4°C, laser set point temperature is 11°C. If module temperature is -25°C, laser set
point temperature is 10°C.
Summary of Contents for GS7000
Page 1: ...Cisco 1 2 GHz GS7000 Node Installation and Operation Guide ...
Page 2: ......
Page 7: ...Contents v Glossary 213 Index 225 ...
Page 8: ......
Page 19: ...Laser Warning Labels xvii ...
Page 20: ......
Page 34: ......
Page 38: ...Chapter 2 Theory of Operation 18 Left Right Segmented ...
Page 84: ...Chapter 2 Theory of Operation 64 1 1 EDR Transmitter 3 2 1 EDR Transmitter 7 ...
Page 96: ...Chapter 3 Installation 76 ...
Page 108: ......
Page 112: ...Chapter 4 Setup and Operation 92 Left Right Segmented ...
Page 116: ...Chapter 4 Setup and Operation 96 Right side Ports 4 5 and 6 illustration ...
Page 143: ...Opening and Closing the Housing 123 ...
Page 158: ......
Page 172: ......
Page 232: ...Appendix C Expanded Fiber Tray 212 ...
Page 244: ......
Page 253: ......