Chapter 4 Setup and Operation
108
2x4 Forward Configuration Modules
Two receivers (RCVR 1 and RCVR 3) each feed 2/3 output ports.
The first receiver (RCVR 1) feeds the right side of the amplifier (Ports 4 and 5/6). The
second receiver (RCVR 3) feeds the left side of the amplifier (Ports 1 and 2/3).
Install the first primary receiver in RCVR 1. Install the second primary receiver in
RCVR 3.
4-way forward segmentable node
The following diagram illustrates forward path signal flow in this configuration
module.