Applying Power to the Node
87
1
Use a true-rms DVM to check for 45 to 90 V AC input voltage at the AC test point
on the power supply module.
2
Check for the various DC output voltages (+24.5, +8.5, -6.0, and +5.5) of the
power supply at the DC test points on the power supply module.
3
Verify that the Power ON LED on the receiver module is on.
4
Carefully close the housing lid. See