Table 7-3
Rear Power Supply LED States
Green PSU Status LED State Amber PSU Fault LED State Event
•
On
•
Off
12 V main on (main power mode)
•
Flashing
•
Off
12 V main off (standby power mode)
•
Off
•
Off
No AC power input (all PSUs present)
•
Off
•
On
No AC power input (redundant supply active)
•
Flashing
•
On
12 V over-voltage protection (OVP)
•
Flashing
•
On
12 V under-voltage protection (UVP)
•
Flashing
•
On
12 V over-current protection (OCP)
•
Flashing
•
On
12 V short-circuit protection (SCP)
•
On
•
On
PSU fan fault/lock (before OTP)
•
Flashing
•
On
PSU fan fault/lock (after OTP)
•
Flashing
•
On
Over-temperature protection (OTP)
•
On
•
Flashing
OTP warning
•
On
•
Flashing
OCP warning
•
Flashing
•
Off
12 V main off (CR secondary PSU is in sleep mode)
Table 7-4
Cisco M690 Content Security Management Appliance Features
Chassis
Two rack-unit (2RU) chassis
Processors
Two E5–2620 v3 processors
Memory
Four 8-GB DDR4-2133 DIMMs
RPC
Accessed through the 1-Gb dedicated port
Data ports
M690: Five 1-Gb BASE-T Ethernet LAN ports
M690-1G and M690-10G: Two 1-Gb or 10-Gb fiber optic ports and one 1-Gb
BASE-T Ethernet LAN port
Management I/O
Supported connectors:
•
One 1-Gb BASE-T Ethernet LAN ports
•
One RS-232 serial port
Power
Two 650 W AC power supplies
Power
consumption
2216 BTU/hr
Cooling
Six fan modules for front-to-rear cooling