Catalyst 6500 Series Switch Software Configuration Guide—Release 8.7
OL-8978-04
Chapter 20 Checking Status and Connectivity
Configuring the Alarm Indication Signal
Successfully deleted entries for port(s) 3/14 vlan(s) 10.
Console> (enable)
Clearing the Ethernet CFM traceroute Database
To clear the contents of the traceroute database, perform one of these tasks in privileged mode:
This example shows how to clear the contents of the traceroute database:
Console> (enable)
clear ethernet-cfm traceroute-database
Traceroute database entries cleared.
Console> (enable)
This example shows how to clear the hold time of the traceroute database:
Console> (enable)
clear ethernet-cfm traceroute-database hold-time
Ethernet TRDB Hold time is cleared and set to default.
Console> (enable)
This example shows how to clear the size of the traceroute database:
Console> (enable)
clear ethernet-cfm traceroute-database size
Ethernet TRDB Size cleared and set to default.
Console> (enable)
Configuring the Alarm Indication Signal
This section describes how to configure the Alarm Indication Signal (AIS) and the Remote Defect
Indication (RDI), which are fault management functions of the Connectivity Fault Management (CFM)
protocol. The CFM module works with 802.3ah Link-OAM to support these new extensions.
Note
AIS-RDI requires Catalyst 6500 series switch software release 8.7(3) or later.
These sections describe how to configure the AIS:
•
Understanding How CFM Works with 802.3ah Link-OAM for AIS-RDI, page 20-55
•
Ethernet Alarm Indication Signal, page 20-55
•
Ethernet Remote Defect Indication, page 20-56
•
ASI and RDI Configuration Guidelines and Restrictions, page 20-56
•
Configuring an Alarm Indication Signal, page 20-57
•
Ethernet Remote Defect Indication, page 20-56
Task
Command
Clear the CFM traceroute database information.
clear ethernet-cfm traceroute-database
Clear the hold time and the size of the traceroute
database.
clear ethernet-cfm traceroute-database
{
hold-time | size
}