Cisco ASR 1002 Router Description

The Cisco ASR 1002 Router –48 VDC power supply LEDs are described in 

Table 8-3

Table 8-3

Cisco ASR 1002 Router –48 VDC Power Supply LEDs 

The output voltage alarm is declared when the output voltage is below the low end of the minimum or 
above the high end of the maximum limits. When the output voltage is above the high end of the 
minimum or below the low end of the maximum limits, the red state will not be activated.

Table 8-4

 shows the –48 VDC power supply output voltage alarm range.

+24 VDC Power Supply for Cisco ASR 1002 Router

This section provides information about the +24 VDC power supplies on the rear of the Cisco ASR 1002 
Router. The recommended branch circuit breaker for the Cisco ASR 1002 24 VDC power 
supply is a 40 A UL listed circuit breaker.

LED Label

LED

Color

Description

INPUT OK

A bi-color LED indicates 
presence of input voltage

Green 

LED illuminates green to signal that the DC power supply 
input voltage is greater than 43.5VDC at turn-on and 
remains green down to 39VDC.

Amber

The LED illuminates amber if the power supply turns off 
due to low input voltage (falls below 39VDC) and 
indicates that there is still a hazard present (voltage on the 
terminal block). The LED remains amber and is active to 
around 20 V +/-5 V. The LED is not illuminated if the 
input is below 15 V.

FAN OK

A bi-color LED indicates 
power supply fan status

Green 

The LED illuminates s green when all fans are 
operational. 

Red

The LED illuminates red when a fan failure is detected.

OUTPUT FAIL

Power supply activity

Red 

When the LED is off, it signals that the DC output voltage 
are within the normal operating range. Output voltage 
between the minimum and maximum limits will not 
create an output fail alarm, and output voltages below the 
minimum or above the maximum will create an Output 
Fail alarm. 

Led illuminates red to indicate that the DC output is out 
of the specified range.

When you turn the power supply on, the red LED 
illuminates for two to three seconds to test LED operation 
before going off. 

Table 8-4

–48 VDC Power Supply Output Voltage Alarm Threshold Ranges

Output

Minimum

Maximum

12V

10.0-11.2V

12.8-13.8V

3.3V

 2.6 - 3.0 V 

None

Summary of Contents for ASR1002 - ASR 1002 Router

Page 1: ...aching the Cable Management Bracket page 8 23 Attaching a Chassis Ground Connection page 8 25 Connecting the Shared Port Adapter Cables page 8 28 Connecting the Console and Auxiliary Port Cables page 8 29 Cisco ASR 1002 Router Power Supplies page 8 30 Connecting a Terminal to the Cisco ASR1000 RP1 Console Port page 8 44 Connecting Cables page 8 46 Auxiliary Connection page 8 46 Cisco ASR 1002 Rout...

Page 2: ...lies are fixed into the chassis and are not upgradeable but the shared port adapters in the SIP are field upgradable This section contains the following topics Front View page 8 2 Rear View page 8 3 Cisco ASR 1002 Router Slot Numbering page 8 4 Front View Figure 8 1 shows the Cisco ASR 1002 Router with modules installed Figure 8 1 Cisco ASR 1002 Router Front View Note The SPAs in subslots 1 3 are ...

Page 3: ...T INPUT FAIL OK OK FAN This unit might have more than one power supply connection All connections must be removed to de energize the unit This unit might have more than one power supply connection All connections must be removed to de energize the unit 0 1 8 7 280288 4 1 5 6 3 2 1 Chassis ESD socket 6 DC power supply captive installation screw 2 DC power supply slot 0 label 7 DC power supply slot ...

Page 4: ...are located in the SPA 0 location and will be addressed as GE 0 0 x The Cisco ASR 1002 Router provides a built in 4 Gigabit Ethernet interface and this SPA is physically located on the Cisco embedded ASR1000 RP1 board The Cisco ASR 1000 Series ESP card is located in slot 1 and labeled as FP0 Figure 8 4 shows the Cisco ASR 1002 Router slot numbering Figure 8 4 Cisco ASR 1002 Router Slot Numbering C...

Page 5: ...or Cisco ASR 1002 Router Description The Cisco embedded ASR1000 SIP10 in the Cisco ASR 1002 Router is built into the Cisco ASR 1002 Router The Cisco embedded ASR1000 SIP10 provides the physical and electrical termination for up to three half height SPAs or one full height and one half height SPA Double wide SPAs are not supported The fourth SPA slot is connected to the built in 4xGE SPA that resid...

Page 6: ...ASR 1002 Router The Cisco ASR 1002 Router power supply module supports the following Cisco power supplies AC power supply operates between 85VAC to 264VAC and DC operates between 40 5 to 72VDC 48 VDC power supply operates between 24 VDC power supply operates STBY ACTV STAT ASR1000 ESP10 PWR 280080 4 3 2 1 No LED Label LED Color Behavior in the Power Up State 1 PWR Power Solid green All power suppl...

Page 7: ...co ASR 1002 Router LED Label LED Color Description INPUT OK Power supply activity Green LED is green and signals that the AC power supply input voltage is greater than 85 V None If LED is not lighted the AC input voltage is less than 70 V or the power supply is turned off For an AC input voltage between 70 V and 85 V the INPUT OK LED can be either on off or flashing FAN OK Power supply fan activit...

Page 8: ...GND The DC power supply is secured into the system chassis with two captive screws mounted on the faceplate Figure 8 7 shows the 48 VDC Power Supply for the Cisco ASR 1002 Router Figure 8 7 48 VDC Power Supply for the Cisco ASR 1002 Router 1 Chassis ESD socket 5 AC power supply fan 2 AC power supply slot number 0 6 AC power supply captive installation screw 3 AC power supply On Off O switch 7 AC p...

Page 9: ...nates green to signal that the DC power supply input voltage is greater than 43 5VDC at turn on and remains green down to 39VDC Amber The LED illuminates amber if the power supply turns off due to low input voltage falls below 39VDC and indicates that there is still a hazard present voltage on the terminal block The LED remains amber and is active to around 20 V 5 V The LED is not illuminated if t...

Page 10: ...ines and electrical requirements of the supply Use the tie wraps to dress the input cable wires there are two tie wrap tabs on the 24 VDC power supply The 24 VDC power supply unit is secured into the system chassis with two captive screws mounted on the faceplate Figure 8 8 shows the 24 VDC Power Supply for the Cisco ASR 1002 Router Figure 8 8 Cisco ASR 1002 Router 24 VDC Power Supply 1 24 VDC ter...

Page 11: ...ne variation Total system power consumption should not exceed 470 watts or output rating of each power supply Note Two power supplies are used for redundant operation System total power consumption shall never exceed rating of one power supply to maintain redundancy LED Label LED Color Description OUTPUT FAIL Power supply activity Red When the LED is off it signals that the 24 VDC output voltage a...

Page 12: ...stress remains within the manufacturer s specified rating Thermal Shutdown The 24 VDC power supply will shut down to protect its components due to excessive internal temperature The 24 VDC power supply then automatically restarts if the internal temperature returns to a safe operating level Installation Methods Cisco ASR 1002 Router is designed for standalone two rail 19 inch rack mount front rail...

Page 13: ...trip does impair a rack mount installation remove the power strip before installing the chassis and then replace it after the chassis is installed Allow sufficient clearance around the rack for maintenance If the rack is mobile you can push it back near a wall or cabinet for normal operation and pull it out for maintenance installing or moving cards connecting cables or replacing or upgrading comp...

Page 14: ...d be installed off the floor Dust that accumulates on the floor is drawn into the interior of the router by the cooling fans Excessive dust inside the router can cause overtemperature conditions and component failures There must be approximately 19 inches 48 3 cm of clearance at the front and rear of the chassis to install and replace FRUs or to access network cables and equipment The Cisco ASR 10...

Page 15: ...ets after the chassis is installed in the rack Step 5 Gather the two cable management brackets and screws shipped with your chassis Figure 8 10 shows cable management brackets attached on the front of the Cisco ASR 1002 Router Note Make certain that the cable management U feature device has the open end pointing upwards when you attach it to the chassis 30007 1 3 2 4 0A PROC ESSOR ONLY 0B 5 6 7 8 ...

Page 16: ...e the width between the inner sides of the two posts or rails must be at least 19 inches 48 26 cm The height of the chassis is 3 47 inches 8 8 cm Airflow through the chassis is from front to back Note If you are using a two post rack secure the rack to the floor surface to prevent tipping and avoid bodily Four post 19 inch equipment rack Inner clearance the width between the inner sides of the two...

Page 17: ...pace between the inner edges of the left front and right front mounting flanges on the equipment rack The space must be at least 17 7 inches 45 cm to accommodate the chassis which is 17 25 inches 43 8 cm wide and fits between the mounting posts on the rack Figure 8 11 Verifying Equipment Rack Dimensions Attaching the Chassis Rack Mount Brackets This section explains how to attach the front and rea...

Page 18: ...t rack mount bracket top hole with the chassis first top hole behind the side vent holes Step 3 Insert and tighten the black screws on one side Step 4 Repeat Step 1 through Step 3 on the other side of the chassis Use black screws to secure the rack mount brackets to the chassis Step 5 Install the chassis in a rack To install the Cisco ASR 1002 Router in a rack go to the Installing the Cisco ASR 10...

Page 19: ...ASR 1002 Router Caution To make installation easier before you mount the ASR 1002 Router in a rack make certain you read which rack mount bracket ear holes to use when positioning the chassis in the rack As a result of using the designated ear holes on the rack mount bracket the cable management bracket installation will be made easier Installing the Cisco ASR 1002 Router in a Rack After installin...

Page 20: ...en the rack posts Step 5 Align the mounting bracket holes with the rack post holes and attach the chassis to the rack Note If you are using a shelf then raise the chassis to the level of the shelf Let the bottom of the chassis rest on the brackets but continue to support the chassis Step 6 Position the chassis until the rack mounting flanges are flush against the mounting rails on the rack Tip To ...

Page 21: ...osest to you and lift it carefully into the rack To prevent injury avoid any sudden twists or moves Figure 8 14 shows where to attach the rear rack mount brackets to the Cisco ASR 1002 Router Figure 8 14 Attaching the Rear Rack Mount Brackets to the Cisco ASR 1002 Router Step 2 Slide the chassis into the rack pushing it back until the brackets meet the mounting strips or posts on both sides of the...

Page 22: ...e two posts or rails must be at least 19 inches 48 26 cm The height of the chassis is 3 47 inches 8 8 cm Airflow through the chassis is from front to back Note Make sure the rack is stabilized Step 1 Optional Install a shelf in the rack to support the Cisco ASR 1002 Router If you are using a shelf then raise the chassis to the level of the shelf Let the bottom of the chassis rest on the brackets b...

Page 23: ...o continue the installation Attaching the Cable Management Bracket The cable management brackets mount to each rack mount bracket on the chassis to provide cable management to both sides of the chassis parallel with card orientation These brackets are screw mounted to the rack mount brackets to allow easy installation and removal of cables The cable management brackets for the Cisco ASR 1002 Route...

Page 24: ...is rack mount and tighten the screw Note Use the package of four screws Figure 8 16 shows the locations at which to attach the front rack mount brackets to the Cisco ASR 1002 Router in a rack Figure 8 16 Chassis Rack Mount Bracket Ear Holes for the Cable Management Brackets Step 3 Using the bottom rack mount ear hole insert the screw through cable management bracket and into the chassis rack mount...

Page 25: ...quipment must be grounded Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available Statement 1024 Before you connect power or turn on power to your chassis you must provide an adequate chassis ground earth conn...

Page 26: ...he wire receptacle on the grounding lug Use the manufacturers s recommended crimping tool to carefully crimp the wire receptacle around the wire this step is required to ensure a proper mechanical connection ASR 1002 stat pwr min maj crit SPA 4XOC 3 POS STA TUS 0 1 2 3 C A A L C A A L C A A L C A A L SPA 4XOC 3 POS STA TUS 0 1 2 3 C A A L C A A L C A A L C A A L STAT QE0 QE1 QE2 QE3 BOOT CARRIER L...

Page 27: ...nection Figure 8 18 shows the parts of the grounding lug Figure 8 18 Parts of the Grounding Lug Step 3 Attach the grounding lug with the wire on the left to avoid having the grounding wire overlapping the power supply Step 4 Locate the chassis ground connector on the side of your chassis 1 Chassis ground connector holes 3 Ground lug screws 2 Grounding lug 4 Ground wire 50536 1 2 3 4 ...

Page 28: ... wire to the appropriate grounding point at your site to ensure an adequate chassis ground This completes the procedure for attaching a chassis ground connection Go to the following cabling sections for information on attaching cables Connecting the Shared Port Adapter Cables The instructions for connecting the cables for the shared port adapter installed in the Cisco ASR 1002 Router are contained...

Page 29: ...le and auxiliary port connectors Before you can use the console interface on the router using a terminal or PC you must perform the following steps Step 1 Before connecting a terminal to the console port configure the terminal to match the chassis console port as follows 9600 baud 8 data bits no parity 1 stop bits 9600 8N1 Step 2 Connect to the port using the RJ 45 to DB 9 cable Note For informati...

Page 30: ...ement device or network Cisco ASR 1002 Router Power Supplies This section describes the Cisco ASR 1002 Router power supplies and how to connect them Connecting AC Input Power to Cisco ASR 1002 Router page 8 31 Connecting 48 VDC Input Power to Cisco ASR 1002 Router page 8 34 Connecting Cisco 24 VDC Power Supply page 8 38 Read the safety warnings before you begin Warning The covers are an integral p...

Page 31: ...tor Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available Statement 1024 Warning This unit has two power supply connections All connections must be removed to de energize the unit Statement 1028 Warning This product relies on the building s installation for short circuit overcurrent protection Ensure that the protective ...

Page 32: ...ways a Leave a small service loop in the AC power cord from the inlet and then secure the power cord through the AC power supply handle as shown in Figure 8 23 Alternatively proceed to Step b 1 Chassis ESD socket 5 AC power supply fan 2 AC power supply slot number 0 6 AC power supply captive installation screw 3 AC power supply On Off O switch 7 AC power supply slot number 1 4 AC power supply LEDs...

Page 33: ...l not be disconnected from the AC power inlet as shown in Figure 8 24 Figure 8 24 Cisco ASR 1002 Router AC Power Supply in Slot 0 and Slot 1 With Power Cord 1 AC power cord 280383 OUTPUT INPUT FAIL OK OK FAN This unit might have more than one power supply connection All connections must be removed to de energize the unit 1 280377 OUTPUT INPUT FAIL OK OK FAN This unit might have more than one power...

Page 34: ...cting an AC power supply in the Cisco ASR 1002 Router Connecting 48 VDC Input Power to Cisco ASR 1002 Router The 48 VDC power supply input connector is a Euro style terminal block A means to provide strain relief to the input wires is provided on the power supply The connection order is negative positive and GND but this is the order from left to right that the terminals appear on the power supply...

Page 35: ...st be removed to de energize the unit OUTPUT INPUT FAIL OK OK FAN 48V 60V 16A This unit might have more than one power supply connection All connections must be removed to de energize the unit 9 8 10 4 5 6 3 0 1 7 1 2 Table 8 9 Cisco ASR 1002 Router 48 VDC Power Supply LEDs LED Label LED Color Description INPUT OK A bi color LED indicates presence of input voltage Green LED illuminates green to si...

Page 36: ...e first and disconnected last Statement 1046 Step 1 At the rear of the router check that the power supply Standby switch is in the Standby see Figure 8 27 position Step 2 Ensure that the negative and positive leads are disconnected from the site power source OUTPUT FAIL Power supply activity Red When the LED is off it signals that the 48 VDC output voltage are within the normal operating range Out...

Page 37: ...le after inserting the lead into its receptacle remove the lead from the receptacle use the wire stripper to cut the stripped end of the lead and repeat Step 3 through Step 5 Step 6 After tightening the receptacle screw for the ground positive and negative 48 VDC input leads use a cable tie to secure the three leads to the power supply faceplate as shown in Figure 8 27 When securing the ground pos...

Page 38: ... Router 24 VDC power supply is a 40 A UL listed circuit breaker Before you begin read these important notices about the 24 VDC power supply The labeling displays 27 VDC INPUT This labeling describes the nominal voltage provided at a cell site Observe the polarity location Unlike the polarity labels of the 48 VDC power supply ground positive negative the polarity labels on the 24 VDC are ground neg...

Page 39: ...e made first and disconnected last Statement 1046 To connect 24 VDC power supply in the Cisco ASR 1002 Router follow these steps Step 1 At the rear of the router check that the power Standby switch is in the Standby position Step 2 Ensure that the positive and negative leads are disconnected from the site power source and the source circuit breaker is turned off Step 3 Using a wire stripper strip ...

Page 40: ...ert the screwdriver at an angle to release the spring while you install the stripped lead wire as shown in Figure 8 30 Figure 8 30 Inserting a Screwdriver Into the 24 VDC Power Supply Terminal Block Step 5 Carefully push the screwdriver at an angle forward until you relieve the spring contact Step 6 With the screwdriver still inserted gently push the lead wire ground lead first in until the copper...

Page 41: ...e the screwdriver to release the spring to tension down on the installed lead wire then perform these steps a Hold the lead wire in place while you are removing the screwdriver b Once the screwdriver is completely removed gently pull on the lead wire to make certain that the lead wire is securely installed 1 Lead wire insulation 2 Copper wire 253167 OUTPUT INPUT FAIL OK OK FAN This unit might have...

Page 42: ...crewdriver being removed while you gently pull on the lead wire Figure 8 33 Removing a Screwdriver from the 24 VDC Power Supply Terminal Block Step 8 Repeat Steps 5 through Step 10 for each lead wire Figure 8 34 shows all the lead wires installed 1 Gently pull on lead wire OUTPUT INPUT FAIL OK OK FAN This unit might have more than one power supply connection All connections must be removed to de e...

Page 43: ...lead is visible after inserting the lead into its receptacle remove the lead from the receptacle use the wire stripper to cut the stripped end of the lead and then reinsert Caution When securing the ground positive and negative 24 VDC input leads to the power supply faceplate leave extra service loop in the ground GND lead to ensure that the ground lead is the last lead wire to disconnect from the...

Page 44: ...35 item 5 Step 11 Turn on the branch source breaker Step 12 Place the power supply standby switch to the On position The power supply LEDs light when power is supplied to the router This completes the steps for installing the 24 VDC power supply in the Cisco ASR 1002 Router Connecting a Terminal to the Cisco ASR1000 RP1 Console Port The Cisco ASR 1002 embedded router processor has an asynchronous ...

Page 45: ...ute Processor 1 must have a console port connection typically to a terminal server if you are running a redundant configuration in the chassis Step 1 Connect one end of the RJ 45 cables to the serial RJ 45 port CON on the Cisco embedded ASR1000 RP1 see Figure 8 36 Figure 8 36 Cisco ASR 1002 Router Console Port Connection on Cisco Embedded ASR1000 RP1 Step 2 Run the cable up and through the cable m...

Page 46: ...m Auxiliary Connection This asynchronous EIA TIA 232 serial port AUX is used to connect a modem to the Cisco ASR 1000 Series Route Processor 1 for remote administrative access Use the following procedure to connect the Cisco ASR 1002 Router to a modem Step 1 Connect one end of the modem cable to the RJ 45 port on the primary Cisco ASR 1000 Series Route Processor 1 labeled AUX For the AUX port conn...

Reviews: