3-15
Cisco 3700 Series Routers Hardware Installation Guide
OL-2180-08
Chapter 3 Installing the Router
Power Connections
Figure 3-17
DC Wire Routing and Attachment for Cisco 3725
Approved Scenarios and Scenarios Not Approved for Dual DC Power Supply Configuration in Cisco 3725 Routers
You can connect a single DC power source to either the A input or the B input. If there are dual power
sources, connect one source to the A input and one source to the B input. Both sources must be the same
polarity (with respect to ground) and voltage (within 0.25 volts). Do not connect –DC grounded and +DC
grounded dual sources to a Cisco 3725 router.
Caution
Dual sources with opposite-polarity grounding can damage equipment.
In
Figure 3-18
, either the positive source terminal or the negative source terminal is tied to ground
.
Figure 3-18
Connecting to One Source Only—Source A or Source B
88035
AL
CD
LP
BEFORE INST
ALLATION
DSU
56K
SEE MANU
AL BEFORE INST
ALLATION
Cable tie
From DC
power
source
Plastic cover
A-
127037
A+
B+
B-
+
A-
A+
B+
B-
+