2-109
Cisco Catalyst Switch Module 3110 and 3012 for IBM BladeCenter System Message Guide
OL-12191-01
Chapter 2 Message and Recovery Procedures
UFAST_MCAST_SW Messages
UFAST_MCAST_SW Messages
This section contains UplinkFast (UFAST) packet transmission messages.
Error Message
UFAST_MCAST_SW-3-PROC_START_ERROR: No process available for
transmitting UplinkFast packets.
Explanation
UplinkFast packets will not be sent because the process could not be created.
Recommended Action
UplinkFast does not work unless you reload the switch software. If this
problem persists even after reload, find out more about the error by using the
show tech-support
privileged EXEC command and by copying the error message exactly as it appears on the console or
system log and entering it in the Output Interpreter tool. Use the Bug Toolkit to look for similar reported
problems. For more information about these online tools and about contacting IBM, see the
Message Traceback Reports” section on page 1-6
.
Error Message
UFAST_MCAST_SW-4-MEM_NOT_AVAILABLE: No memory is available for
transmitting UplinkFast packets on Vlan [dec].
Explanation
UplinkFast packets will not be sent on a VLAN due to memory limitations. [dec] is the
VLAN ID.
Recommended Action
Reduce other system activity to ease memory demands.
VQPCLIENT Messages
This section contains VLAN Query Protocol (VQP) client messages.
Error Message
VQPCLIENT-2-CHUNKFAIL: Could not allocate memory for VQP.
Explanation
An error occurred when the system tried to allocate memory for the VQP client.
Recommended Action
Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Enter the
show
tech-support
user EXEC command to gather data that might help identify the nature of the error.
Use the Bug Toolkit to look for similar reported problems. If you still require assistance, contact
IBM technical support and provide the representative with the gathered information. For more
information about the online tools and about contacting IBM, see the
Error Message
VQPCLIENT-2-DENY: Host [enet] denied on interface [chars].
Explanation
The VLAN Membership Policy Server (VMPS) has denied access for the given host
MAC address to an interface. [enet] is the host MAC address, and [chars] is the interface name.
Recommended Action
No action is normally required. If you think that the host should have been
allowed access, verify the configuration on the VMPS.