Error Message
SW_VLAN-4-STARTUP_EXT_VLAN_CONFIG_FILE_FAILED: Failed to configure
extended range VLAN from startup-config. Error [chars].
Explanation
The VLAN software failed to use an extended-range VLAN configuration from the
startup configuration file. All extended-range VLAN configurations are lost after the system boots
up. [chars] is a description of the error code.
Recommended Action
No action is required.
Error Message
SW_VLAN-4-VLAN_CREATE_FAIL: Failed to create VLANs [chars]: [chars].
Explanation
The specified VLANs could not be created. The port manager might not have completed
the VLAN creation requests because the VLANs already exist as internal VLANs. The first [chars]
is the VLAN ID, and the second [chars] describes the error.
Recommended Action
Check the internal VLAN usage by using
show vlan internal usage
privileged
EXEC command, reconfigure the feature that is using the internal VLANs, and try to create the
VLANs again. If this message appears again, copy the message exactly as it appears on the console
or in the system log. Research and attempt to resolve the error by using the Output Interpreter. Enter
the
show tech-support
user EXEC command to gather data that might help identify the nature of
the error. Use the Bug Toolkit to look for similar reported problems. If you still require assistance,
contact IBM technical support and provide the representative with the gathered information. For
more information about the online tools and about contacting IBM, see the
Traceback Reports” section on page 1-6
Error Message
SW_VLAN-4-VTP_INTERNAL_ERROR: VLAN manager received an internal error
[dec] from vtp function [chars] [chars].
Explanation
The VLAN manager received an unexpected error code from the VTP configuration
software. [dec] is the error code, the first [chars] is the VTP function, and the second [chars] is the
error-code description.
Recommended Action
Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Enter the
show
tech-support
user EXEC command to gather data that might help identify the nature of the error.
Use the Bug Toolkit to look for similar reported problems.If you still require assistance, contact IBM
technical support and provide the representative with the gathered information. For more
information about the online tools and about contacting IBM, see the
.