background image

VCC-FC60FR19CL  

Rev.900-729-31-00 

   

©2011 CIS Corporation. All rights reserved. 

 

 
1.

 

Scope of Application 

 

This is to describe VCC-FC60FR19CL, 4M resolution, Camera Link Color CMOS Camera.     
All specifications contained herein are subject to change without prior notice.    Reproduction in whole or in 
part is prohibited. 
 
2.  Handling Precautions 
 
The camera must not be used for any nuclear equipments or aerospace equipments with which mechanical 
failure or malfunction could result in serious bodily injury or loss of human life.  Our warranty does not 
apply to damages or defects caused by irregular and/or abnormal use of the product.     
 
Please observe all warnings and cautions stated below.     

Our warranty does not apply to damages or malfunctions caused by neglecting these precautions.

 

 

z

 

Do not use

 

or store

 

the camera in the following extreme conditions: 

¾

 

Extremely dusty or humid places. 

¾

 

Extremely hot or cold places (operating temperature –5  to +4

5 )

 

¾

 

Close to generators of powerful electromagnetic radiation such as radio or TV transmitters. 

¾

 

Places subject to fluorescent light reflections. 

¾

 

Places subject to unstable (flickering, etc.) lighting conditions. 

¾

 

Places subject to strong vibration. 

 

z

 

Remove dust or dirt on the surface of the lens with a blower. 

 

z

 

Do not apply excessive force or static electricity that could damage the camera. 

 

z

 

Do not shoot direct images that are extremely bright (e.g., light source, sun, etc.), and when camera   

 

is not in use, put the lens cap on.   

 

z

 

Follow the instructions in Chapter 6, “External connector pin assignment” for connecting the camera. 

  Improper connection may cause damages not only to the camera but also to the connected devices. 

 

z

 

 

Confirm the mutual ground potential carefully and then connect the camera to monitors or

 

 

    computers.    AC leaks from the connected devices may cause damages or destroy the camera. 

 

z

 

 

Do not apply excessive voltage. (Use only the specified voltage.)  Unstable or improper power 

 

    supply voltage may cause damages or malfunction of the camera.

 

Summary of Contents for VCC-FC60FR19CL

Page 1: ...VCC FC60FR19CL Rev 900 729 31 00 2011 CIS Corporation All rights reserved 4M Resolution CMOS Color Camera Link VCC FC60FR19CL Product Specification Operational Manual CIS Corporation English ...

Page 2: ... Signals Timing 1Tap Base Configuration Mode 17fps 15 7 3 Horizontal Synchronous Signals Timing 2Tap Base Configuration Mode 34fps 16 7 4 Vertical Synchronous Signals Timing 2Tap Base Configuration Mode 34fps 16 7 5 Horizontal Synchronous Signals Timing 4Tap Medium Configuration Mode 68fps Initial Setting 17 7 6 Vertical Synchronous Signals Timing 4Tap Medium Configuration Mode 68fps 17 7 7 Horizo...

Page 3: ...or cold places operating temperature 5 to 4 5 Close to generators of powerful electromagnetic radiation such as radio or TV transmitters Places subject to fluorescent light reflections Places subject to unstable flickering etc lighting conditions Places subject to strong vibration z Remove dust or dirt on the surface of the lens with a blower z Do not apply excessive force or static electricity th...

Page 4: ...output Features Global shutter CMOS sensor is utilized Camera Link Base Medium and Full Configuration are supported Fixed trigger shutter mode pulse width trigger shutter mode and internal trigger mode are operable Full frame rates and video output format are as follows Free Software CIS control panel software for evaluation purpose only is downloadable via our web Optional Accessories Mount conve...

Page 5: ...eed 1 68s OFF Gain 12dB and Medium Configuration mode 9 Dust or stains in optical system No dust or stain shall be detected on the testing screen with setting the camera aperture at F16 10 Power requirements DC 12V 10 12pins circular connector or PoCL 11 Power consumption 2 0W at DC 12V IN 4Tap Medium Configuration mode Full frame scan output Initial setting 3 0W at DC 12V IN 8Tap Full Configurati...

Page 6: ...00G for X Y and Z 6 directions without package 24 Operation environment Temperature Performance guaranteed temperature 0 40 Camera operation guaranteed temeprature 5 45 All the specifications specified in this manual is guaranteed under performance guaranteed temperature All the camera functions operate normally under operation guaranteed temperature Humidity RH 20 80 with no condensation 25 Stora...

Page 7: ... 3 Trigger Input Polarity Positive Negative Selectable Polarity is selectable with Address 011 Pulse Width 10μs min Approx 2 frames Functionally no upper limitation is set but noises such as dark noises and shadings might be noticeable at long time exposure Trigger Input 11pin 12pins circular connector LVTTL Selectable with address 012 CC1 Camera Link input LVDS 4 Partial Scan Selection General Pu...

Page 8: ...VCC FC60FR19CL Rev 900 729 31 00 2011 CIS Corporation All rights reserved 8 4 3 CMOS Spectral Response Representative Value Lens charcteristics and luminous source charcteristics are not considered ...

Page 9: ...8 1 2048 Line 512 1024 1536 513 1025 1537 2048 Line 2048pixel 1 512 1024 1536 513 1025 1537 256 768 1280 257 769 1281 1792 1793 2048 256 256 256 256 256 256 256 256 4 4 Video Output Format 1 1Tap Base Configuration Mode 17fps 2 2Tap Base Configuration Mode 34fps 3 4Tap Medium Configuration Mode 68fps Initial Setting 4 8Tap Full Configuration Mode 135fps ...

Page 10: ...0s 1 5000s 1 5000s 1 5000s 11 1 10000s 1 10000s 1 10000s 1 10000s 12 1 20000s 1 20000s 1 20000s 1 20000s 13 1 30000s 1 30000s 1 30000s 1 30000s 14 1 45000s 1 45000s 1 45000s 1 45000s 15 1 50000s 1 50000s 1 50000s 1 50000s 16 Manual Shutter Refer to Address 009 and 010 White Balance 003 0 Through 1 3200K 2 Through 3 Through 4 Manual White Balance Refer to Address 049 050 051 052 Trigger Shutter Mod...

Page 11: ...t L signal to the pin No 4 of the 12pins circuclar connector or disconnect Partial Scan Start Position 1 016 017 0 2047 Set the data of address 015 to 001 Address 016 MSB and address 017 LSB makes total 16bit Camera internal H Sync ON OFF of trigger input signal 018 0 OFF 1 ON Partial Scan Effective Line Number 1 019 020 0 2048 Set 0 when not in use Set the data of address 015 to 001 Address 019 M...

Page 12: ...en not in use Set the data of address 015 to 001 Address 019 MSB and address 020 LSB makes total 16bit Partial Scan Start Position 2 207 208 0 2047 Partial Scan Effective lines 2 209 210 1 2048 Set 0 when not in use Partial Scan Start Position 3 211 212 0 2047 Partial Scan Effective lines 3 213 214 1 2048 Set 0 when not in use Partial Scan Start Position 4 215 216 0 2047 Partial Scan Effective lin...

Page 13: ...onnector control will be invalid 2 General Purpose Output 1 4 The following output signals can be selected by serial communication commands Output Signals Address Data Output 1 034 0 HD output Output 2 035 1 FVAL output Output 3 036 2 Exposure output Output 4 037 3 TRIG Input EN output Pin No Initial Settings 1 GND 2 Power Input DC 12V 3 GND 4 General Purpose Input 1 Full frame scan Partial scan 1...

Page 14: ... at Medium Full Configuration mode please contact the frame grabber board manufacturer to make sure that there would be no problem with the above connection 2 CL Set the switch when using non PoCL supported frame grabber board Please make sure that the power of feeding side is OFF when changing the switch setting If the switch setting is changed while power distribution malfunction may occur Pin N...

Page 15: ...046 2047 2048 2047 2048 1 2 FVAL OUT 1Frame 2053H 58 9ms Effective Line 2048H Effective Line DVAL OUT LVAL OUT Effective Line V Blanking 5H Read OUT Pulse Exposure Time 1 Exposure OUT 1 Exposure Time Address 009 010 Min0 58 7ms Max16383 7 4μs 2048 1 1 1 H 28 667μs Video OUT 2048 7 Timing Chart 7 1 Horizontal Synchronous Signals Timing 1Tap Base Configuration Mode 17fps 7 2 Vertical Synchronous Sig...

Page 16: ...T HD OUT 80 CLK FVAL OUT 1Frame 2054H 29 4ms Effective Line 2048 H Effective Line DVAL OUT LVAL OUT Effective Line V Blanking 6H Read Out Pulse Exposure Time 1 Exposure OUT 2048 1 1 1 H 14 333μs Video OUT 1 Exposure Time Address 009 010 Min0 29 4ms Max8191 7 4μs 2048 7 3 Horizontal Synchronous Signals Timing 2Tap Base Configuration Mode 34fps 7 4 Vertical Synchronous Signals Timing 2Tap Base Confi...

Page 17: ...Camera Link Port B Camera Link Port A 1 2 1025 1026 513 514 1 2 Port A Port B Port C Port D Video OUT 511 1023 1535 2047 HD OUT 80 CLK 2047 2048 511 512 1535 1536 1023 1024 1024 1025 1026 512 513 514 1536 1537 1538 2048 2048 1 1 2048 7 5 Horizontal Synchronous Signals Timing 4Tap Medium Configuration Mode 68fps Initial Setting 7 6 Vertical Synchronous Signals Timing 4Tap Medium Configuration Mode ...

Page 18: ...mera Link Port G Camera Link Port F Camera Link Port E Camera Link Port D Camera Link Port C Camera Link Port B Camera Link Port A Port A Port B Port C Port D Port E Port F Port G Port H Video OUT HD OUT 80 CLK 2048 1 1 2048 7 7 Horizontal Synchronous Signals Timing 8Tap Full Configuration Mode 135fps 7 8 Vertical Synchronous Signals Timing 8Tap Full Configuration Mode 135fps ...

Page 19: ... Trigger operation is CLK Sync HV Sync Reset The delay time Exposure Time Delay from detecting trigger edge in the camera to starting exposure is 370ns Triggers can be accepted even when outputting video signals However trigger signals for exposure to start the next video output prior to the completion of video transmission for the prior video output signals can not be accepted If the edge part of...

Page 20: ...ut prior to the completion of video transmission for the prior video output signals can not be accepted If the edge part of trigger signals is overlapped with video outputting period 1 line noise may detected on the video output screen To input trigger signals during video output period set the data of address 018 to 001 Trigger input signal camera internal H sync ON External trigger signals are s...

Page 21: ...the trigger With serial commands pulse width cycle and numbers to repeat for the trigger signals generated in the camera can be set Using internal trigger mode several images can be taken automatically While internal trigger mode operation external trigger inputs shall be ignored in the camera Refer to the below A Internal Trigger Pulse Width Address 040 041 1 3 583us 3 583us 234 8ms Setting Condi...

Page 22: ...Setting Partial scan start position 1 Address 016 017 Partial scan start position 3 Address 211 212 Partial scan effective lines 2 Address 209 210 Partial scan start position 2 Address 207 208 Partial scan effective lines 3 Address 213 214 0 2047 Partial scan effective lines 1 Address 019 020 Partial scan effective lines 2 Address 209 210 Partial scan effective lines 3 Address 213 214 Partial scan...

Page 23: ...r 1 line Time for 1 line Camera Mode Time for 1 Line 1Tap Base Configuration Mode 28 667μs 2Tap Base Configuration Mode 14 333μs 4Tap Medium Configuration Mode 7 167μs 8Tap Full Configuration Mode 3 583μs Setting Example Line numbers at partial scan setting the number can be set from 1 line However consumption current will exceed several hundred mA so that the margin of camera power capacity shall...

Page 24: ...0 11 12 13 14 Camera No Process code Remote controller address Remote controller data CR 000000 fixed R Read mode Please refer to the address table of Section 5 Function Settings 000 255 0 Dh W Write mode C Camera mode Camera number Camera No is fixed with 6 bytes numerical strings 000000 Process code Input any one of R W or C to the process code R read mode is to read the data of remote controlle...

Page 25: ...her than specified since it may cause the damages or malfunction of the camera Remote controller data Set the decimal number 000 255 for the remote controller data Please be noted to set any dummy data at read control mode CR Be sure to input CR to confirm the end of the command Note The data set with 2 Byte shall be set with High Byte first then set with Low Byte The camera rewrites the internal ...

Page 26: ...Scan Mode Camera H Sync of Trigger Input Signal ON OFF 018 0 OFF Output Image Flip Vertical 021 0 Normal General Purpose Input 1 022 1 Effective Baud Rate 030 0 9600bps Camera Mode 031 1 4Tap Medium Configuration Mode Exposure Polarity 032 0 Positive General Purpose Output 1 034 0 HD Output General Purpose Output 2 035 1 FVAL Output General Purpose Output 3 036 2 Exposure Output General Purpose Ou...

Page 27: ...atum Plane A Inclination of optical axis to datum plane B Datum Plane A 910 017 00 00 Dimensions from datum plane A to the center of the lens mount Inclination of the effective pixels Theta to the datum plane A is 1 9 0 0 3 Un de r 0 5 M42 1 Depth 4 The center of the effective pixels shall be within 0 6 phai to the center of the lens mount 1 Unit mm 11 CMOS Optical Axis Accuracy ...

Page 28: ...6 In Air Product Name Label Position PoCL CL CL1 CL2 DC IN 11 11 33 0 15 5 0 15 Screw length of the lens from the lens mount surface shall be under 4mm And protruding portion shall be under 4mm 999 556 00 01 11 11 33 0 15 5 0 15 2 M4 Depth 4 same as the back side 4 5 M42 1 Depth 4 4 M4 Depth 4 2 M4 Depth 4 same as the back side Unit mm 12 Dimensions ...

Page 29: ...n this product specification operation manual z In case damage or losses are caused by malfunction or other problems resulting from use of equipment or software that is not specified z In case damage or losses are caused by repair or modification conducted by the customer or any unauthorized third party such as an unauthorized service representative z Expenses we bear on this product shall be limi...

Reviews: