VCC-FC60FR19CL
Rev.900-729-31-00
©2011 CIS Corporation. All rights reserved.
24
9.
Remote Communication Function
Via camera link cable, the camera can be controlled.
(1)
The settings for RS232C
Baud rate
:
9600bps (Initial Setting)
19200bps, 38400bps, 57600bps, 115200bps
Data :
8bit
Stop bit
:
1bit
Parity :
None
XON/XOFF :
Not controlled
* Baud rate can be changed with address 030. Please reboot the camera after changing baud rate setting.
(2)
Control code
・
The total control code is 14 bytes, which conforms to ASCII code.
・
The control code consists of camera No. process code, remote controller address, remote
controller data, and CR. Execute Read/Write through PC, and the camera will reply the data.
1 2 3 4 5 6
7th
Byte
8 9 10
11
12
13
14
Camera No.
Process code
Remote controller
address
Remote controller data
CR
000000: fixed
“R” Read mode
Please refer to the
address table of Section
5. Function Settings.
000
~
255
0 Dh
“W” Write mode
“C” Camera mode
Camera number
Camera No. is fixed with 6 bytes numerical strings, “000000”.
Process code
Input any one of R, W, or C to the process code.
R (read mode) is to read the data of remote controller address.
Please be noted to set any dummy data (000
~
255) to 11
th
~
13
th
, since a command shall
consists of 14 bytes.
W (write mode) is to write the data to the remote controller address.
Please be noted that the data cannot be saved into EEPROM of the camera.
(Reboot the camera, and the data is reset to the initial setting.)
To save the data into EEPROM, please refer to Section 5. Function Settings.
C is the code to send the data back from the camera.
Note: Do not set code C when sending the data from PC side.