VCC-FC60FR19CL
Rev.900-729-31-00
©2011 CIS Corporation. All rights reserved.
20
7.10.
Pulse Width Trigger Shutter Mode
□
This is the mode to start exposure with external input trigger signals, and set the exposure time with
pulse width of the trigger signals.
□
Trigger operation is CLK Sync. HV-Sync Reset. The delay time (Exposure Time Delay) from
detecting trigger edge in the camera to starting exposure, and from detecting trigger end edge to
completing exposure is 370ns.
□
Pulse width is min. 10
μ
s to approx. 2 frames. Functionally, there is no upper limitation, but noises
such as dark noises and shadings may be noticeable at long time exposure.
□
Triggers can be accepted even when outputting video signals. However, trigger signals for
exposure to start the next video output prior to the completion of video transmission for the prior
video output signals can not be accepted.
If the edge part of trigger signals is overlapped with video outputting period, 1 line noise may
detected on the video output screen. To input trigger signals during video output period, set the
data of address 018 to 001 (Trigger input signal, camera internal H sync ON). External trigger
signals are synchronized with camera internal H signals so that approx. 3.583
μ
s jitter to Exposure
Time delay would occur.
Effective Line : 2048H
Effective Line
~ ~
Exposure Out
2048
1
Trigger IN
(Read Out Pulse)
LVAL Out
FVAL Out
Video Out
DVAL Out
~ ~
1
Effective Line
Trigger input ignore period
Exposure Time
Exposure Time Delay
Exposure Time Delay
(A)
Trigger Input EN
Exposure Out
FVAL Out
~ ~
LVAL Out
1 Tap Base Configuration Mode
137
μ
s
2 Tap Base Configuration Mode
87
4 Tap Medium Configuration Mode
62
8 Tap Full Configuration Mode
49
LVAL Width Don' t Care
(3H period)
μ
s
μ
s
μ
s
204
8