VCC-FC60FR19CL
Rev.900-729-31-00
©2011 CIS Corporation. All rights reserved.
25
X is the code to respond when error is detected by the camera side.
Details of the detected error can be checked with 4 lines of the 3
rd
to 6
th
byte.
0101: Abnormal address value
0102: Abnormal command
0103: Abnormal data value
0104: Abnormal data length (over 14byte)
Remote controller address
Note: Do not write the data into the address other than specified, since it may cause
the damages or malfunction of the camera.
Remote controller data
Set the decimal number (000
~
255) for the remote controller data. Please be noted to set any
dummy data at read control mode.
CR
Be sure to input “CR” to confirm the end of the command.
※
Note: The data set with 2 Byte shall be set with High Byte first, then set with Low Byte. The
camera rewrites the internal resister when receiving Low Byte.
(3)
Data Save
Input data 083 or 053 into the address 255 to save the data to EEP-ROM.
(4)
Initial Settings
Input data 083 or 053 into the address 254 to return to the initial settings.