VCC-FC60FR19CL
Rev.900-729-31-00
©2011 CIS Corporation. All rights reserved.
14
1
14
13
26
1
14
13
26
(Base Configuration)
(Medium / Full Configuration)
(CN2)
(CN3)
CL
PoCL
(CN1)
(SW1)
6.2.
Camera Link Connector
12226-1100-00PL (SUMITOMO 3M)
Connector (CN3)
Connector (CN2)
6.3.
PoCL Selection Switch (SW1)
(1)
PoCL
・・・
Set the switch when feeding power via the frame grabber board with PoCL
supported.
※
When the switch is set to PoCL side, power feeding line of CN2 (on Base Configuration
connector side) will be connected to the camera internal power input. At this time, power feeding
line of CN3 (on Medium/Full Configuration connector side) shall be OPEN. When using at
Medium/Full Configuration mode, please contact the frame grabber board manufacturer to make
sure that there would be no problem with the above connection.
(2)
CL
・・・
Set the switch when using non-PoCL supported frame grabber board.
Please make sure that the power of feeding side is OFF when changing the switch setting.
If the switch setting is changed while power distribution, malfunction may occur.
Pin No.
Pin No.
Pin No.
Pin No.
1
NA
14
GND
1
GND/
+12V(PoCL)
14
GND
2 Y0-
15 Y0+
2 X0-
15 X0+
3 Y1-
16 Y1+
3 X1-
16 X1+
4 Y2-
17 Y2+
4 X2-
17 X2+
5 Yclk-
18 Yclk+
5 Xclk-
18 Xclk+
6 Y3-
19 Y3+
6 X3-
19 X3+
7
100
Ω
20 Terminated
7 SerTC+
20 SerTC-
8 Z0-
21 Z0+
8 SerTFG-
21
9 Z1-
22 Z1+
9 CC1-
(Trigger IN -)
22
CC1+ (Trigger IN +)
10 Z2-
23 Z2+
10 100
Ω
23 Terminated
11 Zclk-
24 Zclk+
11 100
Ω
24 Terminated
12 Z3-
25 Z3+
12 100
Ω
25 Terminated
13
GND
26
NA
13
GND
26
GND/
+12V(PoCL)