VCC-16MV02
Rev.905-0163-00
©2018 CIS Corporation. All rights reserved.
28
□
Additional registration of defective pixels by users (Address 101).
This is the function to register any defective pixels by specifying its coordinate.
There are two parameters as commands.
The first parameter:
X Coordinate
The second parameter: Y Coordinate
When the same defective pixel as the one registered at our Ex-factory was specified, it should be ignored.
□
Deletion of defective pixels data registered by users (Address 102).
This is the function to delete the defected pixels data detected and registered by the users with specifying its
coordinate. There are two parameters as commands.
The first parameter:
X Coordinate
The second parameter: Y Coordinate
Only the registered data by users, with Address 100 or Address 101, can be deleted.
The data registered at our Ex-factory cannot be deleted by this command.
□
Entire deletion of defective pixels data registered by users (Address 103).
This is to delete all defective pixels data detected and registered by the users, with Address 100 and Address 101.
Please execute this when you wish to redo your detection and registration from the beginning, or when you wish to
restore all the registration to the factory settings. This can be executed by SU 103 1.