Specifications
4.1.
General Specifications
(1)
Pickup device
Device Type
Diagonal length 17.6mm (1.1type) Global shutter B/W CMOS
Effective pixel number
4096(H) × 3000(V)
Unit cell size
3.45μm(H) × 3.45μm(V)
(2)
Video Output Frequency
Pixel Clock
84.86MHz
2tap Configuration mode:
Horizontal Frequency 40.947KHz Horizontal Clock 2080CLK
Vertical Frequency
13.324Hz
Scanning Lines 3062H
4tap Configuration mode:
Horizontal Frequency 81.593KHz Horizontal Clock 1040CLK
Vertical Frequency
26.647Hz
Scanning Lines 3062H
8tap Configuration mode:
Horizontal Frequency 163.19KHz Horizontal Clock 520CLK
Vertical Frequency
53.294Hz
Scanning Lines 3062H
10tap Configuration mode: Horizontal Frequency 192.86KHz Horizontal Clock 440CLK
Vertical Frequency
62.984Hz
Scanning Lines 3062H
(3)
Sync system
Internal Sync. System
(4)
Video output
2Tap Base Configuration
4Tap Medium Configuration
8Tap Full Configuration
8Tap10bit Configuration
10Tap8bit Configuration
(5)
Resolution
3000TV lines
(6)
Output format
Sensor AD
10bit
Camera Link Output
8bit / 10bit B/W output
(7)
Sensitivity
F5.6
400lx (Shutter speed 1/27s(OFF), Gain 0dB, 4tap8bit Configuration mode)
(8)
Minimum illumination
F1.4 0.11 lx (Shutter speed 1/27s(OFF), Gain +36dB, 4tap8bit Configuration mode)
(9)
Power Requirements
DC+12V±10% 12pins circular connector or PoCL
(10)
Power consumption
3.6 W (DC+12V IN, 4Tap 8bit Configuration mode, Full frame scan output)
4.0 W (DC+12V IN, 10Tap 8bit Configuration mode, Full frame scan output)
(11)
Dimensions
Please refer to overall dimension drawing. (H:55mm W:55mm D:25mm Excluding projection)
(12)
Weight
Approx. 100g
(13)
Lens mount
M42 mount
※
Please refer to overall dimension drawing.
(14)
Optical axis accuracy
Please refer to drawing for CMOS Optical Axis Accuracy.
(15)
Gain variable range
0dB ~ +36dB (Guaranteed range)
(16)
Shutter speed variable
range
OFF ~ Approx. 1/51,000s (at 10tap mode)
(17)
Trigger mode
Fixed shutter trigger mode, Pulse width shutter trigger mode
(18)
Partial scan
Full frame scan ~ 4 lines (4 lines/step)
(19)
Safety/Quality standards
UL: Conform to UL Standard including materials and others.
CE
EMC
2014/30/EU
Emission
: EN61000-6-4:2007+A1:2011
Immunity
: EN61000-6-2:2005
RoHS
2011/65/EU
Conformity Standards EN50581 (RoHS 2)
(20)
Durability
Vibration
Acceleration
: 98m/s
2
(10G)
Frequency
: 20 ~ 200 Hz
Direction
: X, Y, and Z 3 directions
Testing time
: 120min for each direction
Shock
No malfunction shall be occurred with 980m/s
2
(100G) for ±X,±Y, and ±Z, 6 directions.
(21)
Operational Environment
Operation Guaranteed Temperature -5 ~ +45
℃
Humidity 20 ~ 80%RH with no condensation
(22)
Storage Environment
-25 ~ +60
℃
Humidity 20 ~ 80%RH with no condensation