Section 10: Rework and Guided Assembly / Rework/Guided Assembly
1000M User’s Guide / page 39
Removing shorts within a net
If the analyzer detects a short, follow these steps:
1.
Press
Advance Display
once to put the analyzer into rework mode. The ana-
lyzer will prompt
Break JX-XX
, where X indicates the adapter position and the
pin number. Break all connections indicated in the display
2.
When you break a connection, the analyzer will prompt the next short. When all
the shorts have been broken, the analyzer will prompt the net and point to which
you should connect JX-XX. Connect JX-XX to the point indicated in the display.
Please see next page...
BREAK JX-XX
Break JX-XX
CONNECT JX-XX
Connect JX-XX