3�4�7�- PHASE-TO-PHASE SINGLE-PHASE NETWORK MEASURING WITH A 2-WIRE CON-
NECTION�
Measurementsystem:
S1
S2
P1
P2
Power
Supply
V
L1
L1
L2
V
L2
POWER SUPPLY
S0+ S0-
OUTPUT
S1
S2
S1
S2
S1
S2
L1
P1
P2
L2
L3
300V ~
Ph-N
Ph-Ph
520V ~
N
V
L3
L2
V
L1
V
P1
P2 P1
P2
LOAD
RS485
A
(+)
B
(-)
GND
Figure 9: Phase-to-phase single-phase measuring with a 2-wire connection�