3�4�6�- TWO-PHASE NETWORK MEASURING WITH A 3-WIRE CONNECTION�
Measurementsystem:
S1
S2
P1
P2
Power
Supply
V
L1
L1
N
POWER SUPPLY
S0+ S0-
OUTPUT
S1
S2
S1
S2
S1
S2
L1
P1
P2
L2
L3
300V ~
Ph-N
Ph-Ph
520V ~
N
V
L3
L2
V
L1
V
P1
P2 P1
P2
V
L1
L2
S1
S2
P1
P2
V
L2
a
b
A
B
a
b
A
B
V
L2
N
N
LOAD
RS485
A
(+)
B
(-)
GND
Figure 8: Two-phase measuring with a 3-wire connection�
16
CVM-C5-xxx-485
Instruction Manual
Summary of Contents for CVM-C5 Series
Page 1: ...INSTRUCTION MANUAL M026B01 03 21A Power analyzer CVM C5 ITF 485 CVM C5 MC 485 CVM C5 mV 485...
Page 2: ...2 CVM C5 xxx 485 Instruction Manual...
Page 50: ...8 CE CERTIFICATE 50 CVM C5 xxx 485 Instruction Manual...
Page 51: ...51 Instruction Manual CVM C5 xxx 485...
Page 52: ...52 CVM C5 xxx 485 Instruction Manual...