5. Installation
Read this manual carefully to ensure the proper and safe installation of the appliance.
!Caution
Install the appliance in the order described in this chapter.
Ø
Please install the appliance in accordance with the applicable national, local and constructional (installation)
regulations.
Ø
Observe the regulations/instructions in this manual.
5.1 Type of gas
The data plate indicates for which type of gas, gas pressure and for which country this appliance is intended.
The data plate can be found on the appliance or can be attached to a chain to which it should remain attached.
!Caution
Check whether the appliance is suitable for the type of gas and the gas pressure used at the location.
5.2 Gas connection
Place a gas tap in the gas pipe in accordance with the applicable regulations.
!Caution
Make sure there is no dirt in gas pipes and connections;
The following requirements apply to the gas connection:
-
use a gas pipe with the correct dimensions, so that no pressure loss can occur;
-
the gas tap must be approved (in the EU this will be the CE mark);
-
you should always be able to reach the gas tap.
5.3 Placing the appliance
!Caution
-
Always place the appliance with a minimum distance of 500 mm from combustible objects or materials;
-
Place the discharge pipes in such a way that situations with risk of fire can never occur;
-
Always place the appliance in front of a wall of non combustible and heat-resistant material;
-
Always maintain a minimum distance between appliance and back wall, if indicated in the dimensional
drawing (Appendix 3, fig. 2);
-
Take sufficient measures to prevent high temperatures of a possible wall behind the chimney breast,
including the materials and/or objects that are behind the wall;
-
Do not cover the appliance and/or do not wrap it in an insulation blanket or any other material;
-
Make sure that the appliance to be installed has a stable position. If applicable, this could also be done by
fixing the extension legs with self-tapping screws.
!Caution
When installing an appliance that has to be built in, take the following into account:
-
The minimum construction dimensions according to Appendix 3, fig. 1 and 2;
-
The construction height of the appliance, which you can determine yourself.
Ø
Provide a gas connection at the location. For details, see section 5.2.
Ø
Make a passage for the flue gas discharge system or the concentric system with the following diameters; for
details, see section 5.7 or 5.8:
-
the pipe di10 mm for a passage through non combustible material;
-
the pipe di100 mm for a passage through combustible material.
!Caution
Starting at section 5.9, you will find additional instructions that are specifically needed for the installation of your
appliance.
UK
Summary of Contents for G20
Page 28: ...E n g l i s h INSTALLATION MANUAL UK 38c 1780 1 B Q T 38c 1778 S C D 4x K 38c 1779 7 5 6 ...
Page 29: ...E n g l i s h INSTALLATION MANUAL UK 38c 1781 1 G A H P 38c 1783 38c 1782 E F R 6x 9 8 10 ...
Page 30: ...E n g l i s h INSTALLATION MANUAL UK A A 38c 1784 A A 38c 1785 G H I L 12 11 ...
Page 31: ...E n g l i s h INSTALLATION MANUAL UK 38c 1786 L J R 38c 1787 14 13 ...
Page 33: ...E n g l i s h INSTALLATION MANUAL UK A B C D 38P 0267 0 38P 0268 A 38P 0269 B 22 21 23 ...
Page 34: ...E n g l i s h INSTALLATION MANUAL UK 38P 0270 C 38P 0271 D 25 24 ...