English
I NS TAL LAT ION M ANUA L
7.3.2 Main burner
!Caution
-
The pilot burner should ignite the main burner within a couple of seconds, and without popping.
-
The main burner(s) must cross the full burner smoothly and without popping and continue to burn.
Ø
Check operation of the main burner from a cold condition (pilot flame off):
Ø
After opening the gas valve, the main burner should burn within a few seconds.
!Tip
-
When the gas valve is opened, the motor will start to run; this is audible.
-
The flame picture and a good flame transfer can only be properly judged if the glass window is installed.
Use the malfunction search diagram (Appendix 1) if the ignition of the main burner does not comply with the
abovementioned requirements.
7.4 Flame picture
The flame picture can only really be assessed when the appliance has been burning for several hours. Volatile
components from paint, materials, etc., which evaporate in the first hours, will affect the flame picture.
!Caution
If the chimney breast has been made of stone-like materials or has a plaster finish, the appliance may only be put
into operation 6 weeks after the chimney breast has been placed, in order to prevent shrinkage cracks.
Ø
Check whether the flame picture is acceptable.
Ø
Consult the malfunction search diagram (Appendix 1) if the flame picture is not acceptable.
UK
Summary of Contents for G20
Page 28: ...E n g l i s h INSTALLATION MANUAL UK 38c 1780 1 B Q T 38c 1778 S C D 4x K 38c 1779 7 5 6 ...
Page 29: ...E n g l i s h INSTALLATION MANUAL UK 38c 1781 1 G A H P 38c 1783 38c 1782 E F R 6x 9 8 10 ...
Page 30: ...E n g l i s h INSTALLATION MANUAL UK A A 38c 1784 A A 38c 1785 G H I L 12 11 ...
Page 31: ...E n g l i s h INSTALLATION MANUAL UK 38c 1786 L J R 38c 1787 14 13 ...
Page 33: ...E n g l i s h INSTALLATION MANUAL UK A B C D 38P 0267 0 38P 0268 A 38P 0269 B 22 21 23 ...
Page 34: ...E n g l i s h INSTALLATION MANUAL UK 38P 0270 C 38P 0271 D 25 24 ...