English
I NS TAL L ATI O N MA N U A L
8. Maintenance
The appliance must be inspected once per year by a skilled installer in the field of gas-fired heating, and repaired if
necessary.
Check at least whether the appliance is working properly and safely.
!Caution
-
Always close the gas tap during maintenance work;
-
Check the gastightness after repair;
-
After replacing thermocouple 1 you should first tighten the gland nut by hand and then give it another
quarter turn with a suitable spanner;
-
You are not allowed to turn the pilot flame lower by using the settings on the gas control.
Ø
If required, clean the following components:
-
the pilot burner (malfunction search diagram, Appendix 1);
-
the space surrounding the pilot burner;
-
the glass pane(s).
!Caution
-
Remove/place the glass pane(s) as described in section 5.10;
-
Remove the deposit on the inside of the glass pane(s) with a damp cloth or a non-abrasive detergent such as
copper polish or a ceramic hot plate cleaner;
-
Avoid/remove fingerprints on the glass pane(s), since otherwise they will burn into the surface;
-
Replace a broken and/or cracked glass pane(s) as described in section 5.10.
!Caution
If necessary, replace the wood or pebble set correctly; for this, see section 5.12.
Ø
Inspect the flue gas discharge system.
!Caution
You must always perform a final inspection.
Ø
Perform the inspection as described in chapter 7.
8.1 Parts
Parts requiring replacement can be obtained from your supplier.
UK
Summary of Contents for G20
Page 28: ...E n g l i s h INSTALLATION MANUAL UK 38c 1780 1 B Q T 38c 1778 S C D 4x K 38c 1779 7 5 6 ...
Page 29: ...E n g l i s h INSTALLATION MANUAL UK 38c 1781 1 G A H P 38c 1783 38c 1782 E F R 6x 9 8 10 ...
Page 30: ...E n g l i s h INSTALLATION MANUAL UK A A 38c 1784 A A 38c 1785 G H I L 12 11 ...
Page 31: ...E n g l i s h INSTALLATION MANUAL UK 38c 1786 L J R 38c 1787 14 13 ...
Page 33: ...E n g l i s h INSTALLATION MANUAL UK A B C D 38P 0267 0 38P 0268 A 38P 0269 B 22 21 23 ...
Page 34: ...E n g l i s h INSTALLATION MANUAL UK 38P 0270 C 38P 0271 D 25 24 ...