Fault finding / Messages
When lights are flashing, you should look
for the reason, and act before using the
toilet.
Resetting the electronic
During cleaning and fault finding, resetting the electro-
nic unit may sometimes be helpful. Do this by pushing
the start button, this will cause a short beep to be
heard. Hold down the button for about 8 seconds until
a long beep is heard, then release button.
Error
Red
Yel.
Sound
What to do
Green
Ash container
must be emptied
Remove and empty ash container.
Remove and empty ash container.
Adjust position of ash container.
Ash container
must be emptied,
toilet locked.
Temperature
sensor is faulty,
shortcircuited or
broken.
Heating circuit
interrupted
Burner fan error
Hatch is jammed
/ bag is jammed
Toilet lid open.
Close toilet lid.
Ventilation fan error
Ash container
in wrong
Flashing
Flashing
Flashing
Flashing
Flashing
Flashing
Flashing
Flashing
Flashing Flashing
Flashing
Lamp
on
Lamp
on
Continuous
Continuous
3
beeps
10
beeps
3
beeps
3
beeps
every 10. sec
10
beeps
10
beeps
1
1
1
2
1
2
1
1
2
1
1
1
Reset the toilet by pressing and holding
down the “start button” for about 8 se-
conds, until you hear a long “beep”. Open
and close the toilet lid. Start incineration.
Please contact our service department, if
the error persists.
Check fan for obstructions.
Reset toilet by holding down ’start’ button
for about 8 seconds until long beep is heard.
Open and close toilet lid. Start incineration. If
error persists, call for service.
3
When toilet is hot:
Reset toilet. Push ’start’
button, but do not put a new bag in the
bowl. If unsuccessful, reset toilet, put new
bag in bowl, pour in 3 cups of water and
push ’start’ button. If still unsuccessful, wait
until toilet has cooled (fan stopped). When
toilet is cool: Reset toilet, open lid and push
’start’ button. Hatch opens and pieces of
paper may be removed manually.
Wait 15 minutes.
Check temperature sensor on right hand
side of toilet. Unscrew grey plug. Push on
fuse inside with finger, do not use any
sharp objects. A click is heard if fuse had
triggered. If so, check inlet/outlet air. If
fuse had not been triggered, call for service.
Reset toilet by holding down ’start’ button
for about 8 seconds until a long beep is
heard. Open and close lid. Start incineration.
If error persists, call for service.
2
Flashing Flashing
Flashing
Other sound/light signals
• >11.5V is the normal operating voltage (green LED shines continuously)
• <11.0V is low voltage (green LED is blinking)
• <10.5V is the minimum permitted battery voltage (10 beeps + green
light blinking continuously after 1.5 min). The gas supply is disconnected.
• <9.5V is a critically low voltage (10 low beeps once and immediate
disconnect)
Error
Red light
Combustion
Yellow light
Start button
Language
select
Status
messages
Power
Green light
Error
message
Empty the
ash container
Toilet locked
container full
Error
main fan
Error hatch
mechanism
Ash container
out of position
Error
burner system
Lid is open
Error
temp.sensor
Error
burner fan
Summary of Contents for CINDERELLA GAS
Page 10: ...10 ...
Page 18: ...18 ...
Page 26: ...26 ...
Page 34: ...34 ...
Page 42: ......
Page 43: ...Serialnumber Notes ...
Page 44: ...Forhandler Dealer Cinderella Eco Solution AS 2017 Vers CG 1 0 EU ...