PCB CONNECTORS
12-4 0-5461
SERVICE MANUAL
180
SERVICE MANUAL
180
12.03 EMC PCB
Art # A-13061
AC4-1
P7
AC4
P2
P1
P5
Power Terminal Name
Terminal function
Signal
P1
Neutral 240 VAC connection into EMC filter
240 VAC Between
Terminal P1 & P2
P2
Active 240 VAC connection into EMC filter
EARTH 3
Mains Earth connection to EMC PCB
0 VAC
AC4
Active 240 VAC out of EMC filter to P1 (pre-charge
start circuit) in the inverter PCB
240 VAC Between
Terminal AC4 / P1
and AC4-1 / P1
AC4-1
Active 240 VAC into the bridge rectifier from the
inverter PCB pre-charge start circuit
P5
DC+ voltage out of the bridge rectifier
340VDC
P7
DC- voltage out of the bridge rectifier
0VDC
Table 12-8 Power Terminal function (connects to EMC PCB)
Input Bridge Rectifier Check in EMC PCB
Testpoint
No.
Input Rectifier
Testing
Multimeter Lead Placement
Testing
Diode Voltage
P5
P1
DC+
to
~ (AC)
Negative (black) meter lead to P5
Positive (red) meter lead to testpoint P1
cathode
-anode
0.2 – 0.8 VDC
P5
AC4-1
DC+
to
~ (AC)
Negative (black) meter lead to P5
Positive (red) meter lead to testpoint AC4-1
cathode
-anode
0.2 – 0.8 VDC
P7
P1
DC-
to
~ (AC)
Positive (red) meter lead to testpoint P7
Negative (black) meter lead to testpoint P1
anode
-cathode
0.2 – 0.8 VDC
P7
AC4-1
DC-
to
~ (AC)
Positive (red) meter lead to testpoint P7
Negative (black) meter lead to testpoint AC4-1
anode
-cathode
0.2 – 0.8 VDC
Table 12-9 Input Rectifier, Multimeter set to measure Diode Voltage
Summary of Contents for WELDSKILL 180
Page 20: ...SERVICE MANUAL 180 INTRODUCTION 2 8 0 5461 This Page Intentionally Blank ...
Page 24: ...SERVICE MANUAL 180 INSTALLATION 3 4 0 5461 This Page Intentionally Blank ...
Page 28: ...SERVICE MANUAL 180 OPERATION 4 4 0 5461 This Page Intentionally Blank ...
Page 54: ...SERVICE MANUAL 180 ROUTINE SERVICE REQUIREMENTS 7 4 0 5461 This Page Intentionally Blank ...
Page 56: ...THEORY OF OPERATION 8 2 0 5461 SERVICE MANUAL 180 This Page Intentionally Blank ...
Page 76: ...KEY SPARE PARTS 13 2 Manual 0 5461 SERVICE MANUAL 180 This Page Intentionally Blank ...
Page 79: ...SERVICE MANUAL 180 This Page Intentionally Blank ...