SERVICE MANUAL
180
SERVICE MANUAL
180
0-5461 6-1 OPERATION
SECTION 6:
TIG (GTAW) WELDING
6.01 Shielding Gas Regulator/Flowmeter Operating Instructions
!
WARNING
This equipment is designed for use with welding grade (Inert) shielding gases only.
Shielding Gas Regulator/Flowmeter Safety
This regulator/flowmeter is designed to reduce and control high pressure gas from a cylinder or pipeline to
the working pressure required for the equipment using it.
If the equipment is improperly used, hazardous conditions are created that may cause accidents. It is the users
responsibility to prevent such conditions. Before handing or using the equipment, understand and comply at
all times with the safe practices prescribed in this instruction.
SPECIFIC PROCEDURES for the use of regulators/flowmeters are listed below.
1. NEVER subject the regulator/flowmeter to inlet pressure greater than its rated inlet pressure.
2. NEVER pressurize a regulator/flowmeter that has loose or damaged parts or is in a questionable condi-
tion. NEVER loosen a connection or attempt to remove any part of a regulator/flowmeter until the gas
pressure has been relieved. Under pressure, gas can dangerously propel a loose part.
3. DO NOT remove the regulator/flowmeter from a cylinder without first closing the cylinder valve and
releasing gas in the regulator/flowmeter high and low pressure chambers.
4. DO NOT use the regulator/flowmeter as a control valve. When downstream equipment is not in use for
extended periods of time, shut off the gas at the cylinder valve and release the gas from the equipment.
5. OPEN the cylinder valve SLOWLY. Close after use.
User Responsibilities
This equipment will perform safely and reliable only when installed, operated and maintained, and repaired in
accordance with the instructions provided. Equipment must be checked periodically and repaired, replaced,
or reset as necessary for continued safe and reliable performance. Defective equipment should not be used.
Parts that are broken, missing, obviously worn, distorted, or contaminated should be replaced immediately.
The user of this equipment will generally have the sole responsibility for any malfunction, which results from
improper use, faulty maintenance, or by repair by anyone other than an accredited repairer.
!
CAUTION
Match regulator/flowmeter to cylinder. NEVER CONNECT a regulator/flowmeter designed for a particular gas or gases to
a cylinder containing any other gas.
Art: A-05087
Figure 6-1: Fit Regulator/flowmeter to Cylinder
Summary of Contents for WELDSKILL 180
Page 20: ...SERVICE MANUAL 180 INTRODUCTION 2 8 0 5461 This Page Intentionally Blank ...
Page 24: ...SERVICE MANUAL 180 INSTALLATION 3 4 0 5461 This Page Intentionally Blank ...
Page 28: ...SERVICE MANUAL 180 OPERATION 4 4 0 5461 This Page Intentionally Blank ...
Page 54: ...SERVICE MANUAL 180 ROUTINE SERVICE REQUIREMENTS 7 4 0 5461 This Page Intentionally Blank ...
Page 56: ...THEORY OF OPERATION 8 2 0 5461 SERVICE MANUAL 180 This Page Intentionally Blank ...
Page 76: ...KEY SPARE PARTS 13 2 Manual 0 5461 SERVICE MANUAL 180 This Page Intentionally Blank ...
Page 79: ...SERVICE MANUAL 180 This Page Intentionally Blank ...