0-5461
9-1
MAIN CIRCUIT DESCRIPTION
SERVICE MANUAL
180
SECTION 9:
MAIN CIRCUIT DESCRIPTION
WARNING
Turn off power and disconnect mains supply plug from receptacle before working on the unit. Allow two minutes for capacitors to
discharge and check that the DC bus voltage has discharged to less than 5VDC, refer to Section 10.04, after disconnection from mains
supply voltage.
Art # A-13056
The 240VAC mains supply voltage is connected via a double pole switch to the input rectifiers on the Main Inverter
Board through an EMC Filter Circuit on the EMC Board. Overvoltage protection is provided by a varistor, 20D511K,
rated at 320VAC/220J in the EMC Board.
Rectifier, B1, output charges the main capacitor bank (C4, C5, C6, C8) to a high DC voltage, 340VDC once J1//
J2 closes, through the Pre-charge Start Circuit. Inrush current limiting is provided by V1 & V2 which are short
circuited by relay J1//J2 after a few seconds.
Summary of Contents for WELDSKILL 180
Page 20: ...SERVICE MANUAL 180 INTRODUCTION 2 8 0 5461 This Page Intentionally Blank ...
Page 24: ...SERVICE MANUAL 180 INSTALLATION 3 4 0 5461 This Page Intentionally Blank ...
Page 28: ...SERVICE MANUAL 180 OPERATION 4 4 0 5461 This Page Intentionally Blank ...
Page 54: ...SERVICE MANUAL 180 ROUTINE SERVICE REQUIREMENTS 7 4 0 5461 This Page Intentionally Blank ...
Page 56: ...THEORY OF OPERATION 8 2 0 5461 SERVICE MANUAL 180 This Page Intentionally Blank ...
Page 76: ...KEY SPARE PARTS 13 2 Manual 0 5461 SERVICE MANUAL 180 This Page Intentionally Blank ...
Page 79: ...SERVICE MANUAL 180 This Page Intentionally Blank ...