SERVICE MANUAL
180
SERVICE MANUAL
180
0-5461 4-1 OPERATION
SECTION 4:
OPERATION
4.01 Overview
Conventional operating procedures apply when using the Welding Power Source, i.e. connect work lead directly
to workpiece and electrode lead is used to hold electrode (Consult the electrode manufacturers information
for the correct polarity). The welding current range values should be used as a guide only. Current delivered
to the arc is dependent on the welding arc voltage, and as welding arc voltage varies between different classes
of electrode, welding current at any one setting would vary according to the type of electrode in use. The
operator should use the welding current range values as a guide, then finally adjust the current setting to suit
the application.
4.02 Power Source Controls, Indicators and Features
1
2
3
4
6
5
7
Front Panel
Rear Panel
Art # A-12796
8
Figure 4-1
1. Process Selection Control
The process selection control is used to select the desired welding mode. Two modes are available, Stick
(MMAW) and Lift TIG (GTAW) modes. Refer to section 5.01 for Stick (MMAW) set-up details or section 6.01
for Lift TIG (GTAW) set-up details.
2. Power Indicator
The power indicator is illuminated when nominal 240V AC mains power is applied to the power source and
the ON/OFF switch located on the rear panel is in the ON position.
Summary of Contents for WELDSKILL 180
Page 20: ...SERVICE MANUAL 180 INTRODUCTION 2 8 0 5461 This Page Intentionally Blank ...
Page 24: ...SERVICE MANUAL 180 INSTALLATION 3 4 0 5461 This Page Intentionally Blank ...
Page 28: ...SERVICE MANUAL 180 OPERATION 4 4 0 5461 This Page Intentionally Blank ...
Page 54: ...SERVICE MANUAL 180 ROUTINE SERVICE REQUIREMENTS 7 4 0 5461 This Page Intentionally Blank ...
Page 56: ...THEORY OF OPERATION 8 2 0 5461 SERVICE MANUAL 180 This Page Intentionally Blank ...
Page 76: ...KEY SPARE PARTS 13 2 Manual 0 5461 SERVICE MANUAL 180 This Page Intentionally Blank ...
Page 79: ...SERVICE MANUAL 180 This Page Intentionally Blank ...