7. battery ChanGe
If the values and adjustments of the
HAC
are to be main-
tained during the battery change, the power-saving mode should be
switched on before the battery is changed (see chap. 5.3).
Battery of
HAC
:
Unscrew counter-clockwise the screwed cap on the reverse side
of the computer with the aid of a coin. Note: do not remove the
foil inside the battery case. Remove the old battery and insert new
3-volt lithium battery type CR 2032 with the plus pole (+) facing up
(below the foil). Close screw cap again.
Do not over twist battery cap!
If no characters or unintelligible characters appear in the display
after the battery change, remove battery again, wait 10 sec. and
insert battery again.
Transmitter belt and handlebar bracket:
Unscrew the battery cap (handlebar bracket: on the upper side,
transmitter belt: on the backside) counter-clockwise and remove the
old battery. Fit a new CR2032 lithium battery, with the plus pole (+)
facing up and replace the cap.
Do not over twist battery cap!
Speed transmitter:
Screw off the battery cap counter-clockwise with the aid of a coin.
Remove the old battery and insert a new 12V battery, type 23A,
plus pole (+) facing up. Close the battery cap.
Please do not discard used batteries in domestic waste, but
discard them on your local recycling-point.
8. Care and maIntenanCe
Do not expose the device to direct sunlight, or too low or high tem-
peratures (below -25°C or above 50°C).
Keep the heart rate transmission belt clean:
Do not wash the transmitter belt in a washing machine, due to the
attached electrodes. To clean the transmitter belt, wipe it carefully
with a detergent for synthetic fabrics. Do not dry in direct sunlight.
The elastic chest belt is washable, but it must be carefully dried
before use.
9. troUble shootInG
Problem
No display is shown
Black display or
display is too slow
no speed displayed
speed or distance
is too high or too low
no heart rate
displayed
heart rate is not
correct or varies
Recording stops
automatically
signal tones in
regular intervals
altitude shows in-
correct value after
start of a recording
Countdown
doesn’t work
1
Cause and / or elimination
- press LL- or UL-button
- check battery
- temperature too high (over 60°C) or display
was disposed too long to direct sunlight
- temperature too low (below -10°C)
- check battery of handlebar bracket and trans-
mitter
- clean contacts on the backside of the
HAC 4000 with alcohol
- check circumference
- check unit of measurement
- check distance between transmitter and handle-
bar bracket (max. 60 cm)
- heart rate receiver is off and must be
activated again (see chap. 5.3)
- check transmitter belt
- skin is too dry/too cold
- malfunction due to electric cables, pace-
makers, etc. after leaving the malfunction
area, the heart rate will be displayed as usual
- distance between HAC 4000 and transmitter
belt is too big (max. 60 cm)
- check, whether a tour was chosen for
comparison (see function comparison,
chap. 5.2)
- check, if countdown is running or heart rate
alarm is switched on
- check altitude home (setting mode 1),
maybe a wrong value is set there
- check whether heart rate – time manager is
switched on