HL 2 – heart rate upper limit 2

Set with UL- or LL-button
Standard value = 120 bpm (beats per minute) 
or the personal upper limit calculated with 

C

ICLO

Zone

®

 

Setting range min. = 30 bpm; max. 240 bpm

HL 2 – heart rate lower limit 2

Set with UL- or LL-button
Standard value = 100 bpm (beats per minute) 
or the personal upper limit calculated with 

C

ICLO

Zone

®

Setting range min. = 30 bpm; max. 240 bpm

Cd 1 – Countdown 1

Set with UL- or LL-button
Standard value = 10 minutes
Setting range = 0 - 99.59 minutes

1.

  Countdown 1 / Countdown 2 is a stop-watch which runs 

backwards (see chap. 5.2, “countdown function“). After starting, the 

HAC

 gives a short signal when CD 1 reaches 0. Then CD 

2 starts automatically, when it reaches 0 it gives short signals for 20 
sec. If only one countdown is necessary, the other must be set to 0.

2.

  These settings are necessary when using the heart rate time 

manager (see chap.6. “special functions”).

Cd 2 – Countdown 2

Set with UL- or LL-button
Standard value = 10minutes
Setting range = 0 - 99.59 minutes

Cc oFF/on – Cadence on/off 

Select with UL- or LL-button
Standard value = oFF
Here the cadence measurement can be swit-
ched on or off (measurement is only possible 
with the optional cadence kit). 

The following two settings only appear, when cadence is switched 
‚on‘.

UL – upper limit for cadence

Set with UL- or LL-button
Standard value = 180 rpm (rounds per minute) 
Setting range min. = 30 rpm; max. 240 rpm

In order to better control your training, a ca-
dence limit (lower and upper limit) can be set. 
When current cadence value is below or above the limits, an optical 
alarm occurs (cadence value starts blinking).

LL  – lower limit for cadence

Set with UL- or LL-button
Standard value = 120 rpm (rounds per minute) 
Setting range min. = 30 rpm; max. 240 rpm

U1 – unit kilometre/mile

Select with UL- or LL-button
The unit of measure for distance and speed 
can be set here (kilometres or miles). 

U2 – Time-of-day display: 24- or 12-hour 

Select with UL- or LL-button
If 12-hour indication is selected, automatically 
also the american date format (month/day) and 
weight unit lbs is chosen.

U3 – Unit °Celsius/°Fahrenheit

Select with UL- or LL-button
The unit of measure for the temperature can be 
set here (°celsius or ° fahrenheit). 

U4 – Unit altimeter meter (m) / 
feet (ft x 10)

Select with UL- or LL-button
The unit of measure for the altitude can be set 
here (meter or feet). 

UPL – Upload Version

Start with short simultaneous pressing of UL- 
and LL-button 
Indicates the firmware-version of the 

HAC

. If there is a newer firmware available 

for your 

HAC

 (see www.ciclosport.

de), you can start the firmware upload at this point with short 
simultaneous pressing both left buttons (UL- and LL-button), that 
is only possible with the optional pc-interface and the program 

HAC

tronic

.

When the upload is finished correctly, normal mode appears in the 
display.

Pd – Power down-mode

Switch on with short simultaneous pressing of 
UL- and LL-button 
Starts the power-saving mode (see chap. 5.3).
To end the power-saving mode, press any 
button.

4.2 setting mode 2

Press LR-button 4 sec.

A – Setting and / or re-adjusting current 
altitude

Set with UL- or LL-button
Setting range = -200m to 9000m or 
2952 ft x10

The current altitude can be adjusted, if e.g. due to variations in the 
air-pressure, the current altitude shown in the 

HAC

 is not 

correct.
A change in the current altitude has no effect on other altitude func-
tions (e.g. total meters). Only if the adjusted altitude is higher than the 
current max. altitude, the max. altitude will be changed to the new 
value.

DST – adjust daily distance

Set with UL- or LL-button   
Standard value = 0 km  
Setting range min. = 0,00 km /m; 
max.= 999,99 km / 621,36 m
(in the display the comma is shown as a colon)

The daily kilometres can be adjusted here, e.g. as a starting point 
in case of tours according to a tour guidebook, if the tour was not 
entered at „0“ km.
This setting does not affect the function total kilometres. There only 
the really ridden kilometres are counted.

JS oFF/on – Ski mode on/off  

Select with UL- or LL-button
If the 

HAC

 is used while skiing, the 

ski speed is only calculated and indicated if this 
function is set ‚on‘.

Summary of Contents for HAC 4000

Page 1: ...CicloSport K W Hochschorner GmbH Konrad Zuse Bogen 8 D 82152 Krailling Internet www ciclosport de e mail ciclosport ciclosport de HAC 4000 Instruction manual...

Page 2: ...1 and bike 2 8 Maximum speed 8 Maximum speed bike 1 or bike 2 8 Current heart rate 8 Average heart rate 8 Maximum heart rate 8 Recuperating heart rate 8 Current ascent descent 8 Average ascent 8 Aver...

Page 3: ...not slip If the breast belt is not long enough a longer breast belt can be acquired from your local bicycle dealer If your skin is too cold or too dry the electrical contact between the skin and the e...

Page 4: ...4 seconds In order to quit a setting mode premature press either the UR or LR button again for 4 seconds The following applies to both setting modes Pressing the respective button mode 1 UR mode 2 LR...

Page 5: ...ith UL or LL button Standard value 70 kg Setting range min 30 kg 66 lbs max 200 kg 441 lbs The body weight is needed for the CICLO Zone calculation AGE age Set with UL or LL button Standard value 30 y...

Page 6: ...dication is selected automatically also the american date format month day and weight unit lbs is chosen U3 Unit Celsius Fahrenheit Select with UL or LL button The unit of measure for the temperature...

Page 7: ...all total values and also all daily values To reset press both left buttons short simultaneous Now all settings are done and the HAC is ready for use 5 Functions Important For the HAC to calculate an...

Page 8: ...the display disappears To reactivate the heart rate receiver choose again the function Current heart rate in the display Average heart rate Sub function of function Current heart rate Indicates the av...

Page 9: ...Sub function of the function Temperature Indicates the highest temperature measured during the tour Range 20 to 60 C resp 20 to 140 F 5 2 Lower display indications Main functions are chosen with LR bu...

Page 10: ...tour Range 0 240 rpm Maximum cadence only in bike mode Sub function of function Cadence Indicates the maximum cadence of the current tour Range 0 240 rpm Number of revolutions only in bike mode Sub f...

Page 11: ...ps of 20 W Note The indicated performance values are approximate They are calculated under the assumption of an average friction wind speed good surface nature of the street and the set total weight T...

Page 12: ...ours training when memory interval is set to 20 sec For this a recording must be started by pressing UL and LL button simultaneous for 4 sec During this recording all important information such as hea...

Page 13: ...ifference in time To cancel the comparison premature press again UL and LL button simul taneous for 4 sec coincidentally the recording is stopped In order to compare tours these tour must be previousl...

Page 14: ...elt clean Do not wash the transmitter belt in a washing machine due to the attached electrodes To clean the transmitter belt wipe it carefully with a detergent for synthetic fabrics Do not dry in dire...

Page 15: ...evice will be sent back COD 11 Technical data HAC Water resistant 30 m not suitable for swimming do not press any button when wet Operating temperature 20 C to 50 C Battery Lithium CR2032 Average batt...

Reviews: