Summary of Contents for 38HV09JS8C

Page 1: ...5 620 114 Document non contractuel Dans le souci constant d am liorer son mat riel CIAT se r serve le droit de proc der sans pr avis toutes modifications techniques Non contractual document With the t...

Page 2: ...imination 1 Votre municipalit a mis en place des syst mes de collecte gr ce auxquels les utilisateurs peuvent se d barrasser de leurs d chets lectroniques gratuitement 2 Lorsque vous achetez un nouvea...

Page 3: ...tion Ne modifiez pas cet appareil en retirant une protection ou en contournant les dispositifs de verrouillage de s curit Il convient que les travaux lectriques soient effectu s en conformit avec le m...

Page 4: ......

Page 5: ...3 Percer le trou dans le mur tape 8 Suspension de l unit int rieure Raccordement des c bles int rieurs 1 Soulevez le panneau avant de l appareil int rieur 2 Ouvrez le couvercle des composants lectriqu...

Page 6: ...t te du boulon de fixation mesure plus de 12mm Dimensions de l appareil ext rieur mm Dimensions de montage mm W H D A B 700 550 275 450 260 770 555 300 487 298 800 554 333 515 340 845 702 363 540 376...

Page 7: ...e cuisine et d autres endroits similaires renforcez l isolation Il convient que la temp rature de r sistance la chaleur de l isolation soit sup rieure 120 C Utilisez des adh sifs sur la partie de racc...

Page 8: ...es uniquement REMARQUE 1 Tous les fils lectriques doivent tre d une dimension conforme au code de c blage lectrique local r gional et national Consultez les codes de construction locaux et le code nat...

Page 9: ...iode o les travaux sont r alis s Il convient que la ventilation permette de dissiper le produit frigorig ne lib r en toute s curit et de pr f rence de le rel cher l ext rieur dans l atmosph re 7 8 V R...

Page 10: ...ATIVES L ENTRETIEN la taille de la charge est adapt e la taille de la pi ce dans laquelle les parties contenant le produit frigorig ne sont install es les appareils de ventilation et les orifices fonc...

Page 11: ...ment pouvant tre stock s ensemble sera d termin par les r glementations locales 7 INFORMATIONS RELATIVES L ENTRETIEN 7 16 PROC DURES DE CHARGEMENT Outre les proc dures conventionnelles de chargement l...

Page 12: ...k shall be stopped and repaired as soon as possible 4 Only qualified service personnel are allowed to access and service this product 5 Any handling of the fluorinated gas in this product such as when...

Page 13: ...from power source before attempting any electrical work Connect the connective cable correctly Wrongly connecting may result in electric parts damaged Use the specified cables for electrical connectio...

Page 14: ...sed to strong winds it is recommended that a wind baffle be used A location which can bear the weight of outdoor unit and where the outdoor unit can be mounted in a level position A location which pro...

Page 15: ...ening the screws 3 Pass the connecting wires from the back of indoor unit and connect to the indoor terminal block Front panel The drain line must not have a trap anywhere in its length must pitch dow...

Page 16: ...tdoor unit and rotate 90 degree to securely assemble them 3 5 INSTALL THE DRAIN PIPE FOR OUTDOOR UNIT unit cm unit cm Base pan hole of outdoor unit Drain hose Field supply Gasket Drain Outlet The moun...

Page 17: ...ve C D Indoor unit flare nuts Check point of indoor unit Check point of outdoor unit A B C D 4 3 REFRIGERANT PIPE NOTE The refrigerant should be charged from the service port on the outdoor unit s low...

Page 18: ...earth connection for functional purposes only CAUTION 60mm 40mm 10mm Power input cord GND 60mm 40mm 10mm GND Connective Cable W 1 2 S L N Power Input To Indoor W 1 2 S L N Power Input To Indoor W 1 2...

Page 19: ...shall be undertaken under a controlled procedure so as to minimise the risk of a flammable gas or vapour being present while the work is being performed 7 3 GENERAL WORK AREA All mintenance staff and...

Page 20: ...hat can be worked on while live in the presence of a flammable atmosphere The test apparatus shall be at the correct rating Replace components only with parts specified by the manufacturer Other parts...

Page 21: ...e labels on the equipment stating the equipment contains flammable refrigerant 20 19 7 19 RECOVERY CAUTION When removing refrigerant from a system either for service or decommissioning it is recommend...

Page 22: ...cos Para su eliminaci n hay varias posibilidades 1 El municipio ha establecido sistemas de recogida en los que se pueden desechar los residuos electr nicos de forma gratuita para el usuario 2 En la co...

Page 23: ...la eliminaci n de cualquiera de las protecciones de seguridad ni se salte ninguno de los interruptores de seguridad El trabajo el ctrico debe llevarse a cabo de acuerdo con el manual de instalaci n y...

Page 24: ......

Page 25: ...Conexi n de cables de la unidad interior 1 Levante el panel frontal de la unidad interior 2 Abra la cubierta de los cables el ctricos de la unidad interior con un destornillador quite la cubierta de...

Page 26: ...nillo de fijaci n debe ser mayor de 12mm Dimensiones unidad exterior mm Dimensiones de montaje mm W H D A B 700 550 275 450 260 770 555 300 487 298 800 554 333 515 340 845 702 363 540 376 3 2 REQUISIT...

Page 27: ...o usando las herramientas de abocardado tal como se indica a continuaci n Di metro exterior A mm M x M n 6 35 mm 8 7 8 3 9 52 mm 12 4 12 0 12 7 mm 15 8 15 4 15 88 mm 19 0 18 6 19 05 mm 23 3 22 9 4 1 4...

Page 28: ...to incorpora una conexi n de toma de tierra solo para fines funcionales AVISO 1 Todos los cables de alimentaci n deben dimensionarse de acuerdo con el c digo de cableado el ctrico nacional Consulte la...

Page 29: ...a ventilaci n debe dispersar de forma segura todo el refrigerante liberado y expulsarlo preferiblemente a la atm sfera externa 7 8 COMPROBACIONES EN EL EQUIPO DE REFRIGERACI N Cuando se cambien compon...

Page 30: ...o de la sala en la que est n instalados los componentes que contienen refrigerante la maquinaria de ventilaci n y las salidas funcionan adecuadamente y no est n obstruidas si se utiliza un circuito d...

Page 31: ...voque una fuga de la carga de refrigerante El n mero m ximo de equipos que se permiten almacenar juntos estar determinado por las regulaciones locales 7 INFORMACI N PARA EL SERVICIO T CNICO 7 16 PROCE...