6.1 Schedule of Function Parameters
6.1 Schedule of Function Parameters
Function
Code
Name
Setting Range
Unit
Min.
Unit
Default
Setting
Operation
Modification
Function
Code
Name
Setting Range
Unit
Min.
Unit
Default
Setting
Operation
Modification
6.1.8 F7 Series Programmable Operation Parameters (Continuation...)
Wobble operation
parameters
LED units digit Remain
LED tens digit wobble control
0: Fixed wobble
1: Variable wobble
LED hundreds digit Wobble
shutdown start selection
0: Start according to the state
memorized before shutdown
1: Restart
LED thousands digit Wobble
status: Memory store or not after
power failure
0: Store the wobble status after
power failure.
1: Do not store the wobble status
after power failure.
Wobble preset frequency
Wobble preset frequency
waiting time
Wobble range
Trip frequency
Wobble cycle:
Triangle rising time
Wobble center frequency
standard
0.00~upper limit frequency
0.00~upper limit frequency
6.1.9 F8 Series Communication Parameters
Host address
Communication
configure
LED units digit
Baud rate selection
LED tens digit data format
0: No parity
1: Even parity
2: Odd parity
LED hundreds digit:
Communication failure
action selection
0: Stop
1: Remain the present state
LED thousands digit:
Remain
Communication
time-out checkout time
Host response delay
gearing rate setting
Host
Modbus