Chapter 4 Operator panel and its Operation
Chapter 4 Operator panel and its Operation
Table 4-2 Monitoring Parameter LED Display List
4.2 Monitoring Parameter Display
Category
Category
Display Code
Display
Code
Name
Name
Unit
Unit
Monitoring
Display
Parameters
Monitoring
Display
Parameters
Output frequency
Setting frequency
Output current
Output voltage
Motor rotation speed
Running linear speed
Setting linear speed
DC bus bar voltage
Input voltage
PID set value
PID feedback value
Analog input AVI
Analog input ACI
Impulse input frequency
Input terminal status
Radiator temperature
Module temperature
Current counter value
Setting counter value
1st diagnostic
failure codes
2nd diagnostic
failure codes
3rd diagnostic
failure codes
0:OC-1
1:OC-2
2:OC-3
3:OU-1
4:OU-2
5:OU-3
6:OU-4
7:LU
8:LP
9:SC
10:OH
11:OL
12:OL
13:EF
14:CE-1
15:CE-2
16:CE-3
17:CE-4
18:CPU
Acceleration running
over current
Deceleration running
over current
Steady-speed running
over current
Acceleration running
over voltage
Deceleration running
over voltage
Steady running over
voltage
Over voltage when
power off
Under voltage of running
Input side open-phase
Power module failure
Radiator over heat
Inverter overload
Motor overload
external equipment failure
COM error
Remain
Current detection error
Keyboard
communication failure
failure
Output frequency of the last failure
Setting frequency of the last failure
Output current of the last failure
Output voltage of the last failure
DC bus bar voltage of the last failure
Module temperature of the last failure
Software edition