1.

5

6

2.

AAA

+

+

1.

Preparation before Use

Power on

Keypad uses 3pcs of AAA batteries.

Loose the screw, open the case

Put in batteries according to the positive and negative signs

Close the rear cover and screw on

Remove the insulating strip for first time.

Note! 

Open the rear cover of keypad will trigger tamper switch, please 

dismiss the alarm by following the disarm instruction in page 20.

When connected with electronic door lock as an access control, 

keypad is suggested to use the specific power supply for access 

control.

To know connection steps, please refer to the instruction manual of electronic 

door lock. The electronic door lock and specific power supply for access control 

should be purchased respectively.

Connect Keypad to Control Panel

Make sure the control panel is in connecting state, input user 

code or admin code on keypad, and then press any key of 

. The connection succeeds after 

one beep.

[Arm] [Disarm] [Stay Mode]

User can remotely control the panel via the keypad after connection.

(To know connection steps, please consult the panel’s manual.)

Connect Keypad with RFID Tag

Input 

 to wake up keypad.

Three beeps mean wrong input.

[admin code   + #]

Wrong input for 6 times continuously, the keypad will be locked for 20 seconds.

Default admin code: 123456

Summary of Contents for KP-700

Page 1: ...Printed in Hong Kong PA OI KP700 EN 2013V1 0 KP 700 Keypad Operation Manual Please read this manual carefully before use Please keep it properly for further reference...

Page 2: ...ock Installation Settings Enter Setup State Delay Arm Speed SOS Dial Keyboard Clicks Disarm by RFID Tag Power Saving Mode Change User Code Change Admin Code Reset Usage 19 20 21 22 22 Arm Disarm Stay...

Page 3: ...lock to work as an access control system for homes and offices When users are leaving rooms just close the door the electronic lock will be locked automatically Before entering house just input the p...

Page 4: ...or RFID reader Arm Disarm Stay mode SOS key RFID wake up key RFID tag card 125KHz can be purchased separately Max 50 pcs are supported Positive and negative terminals for battery Battery slot Rear cov...

Page 5: ...know connection steps please refer to the instruction manual of electronic door lock The electronic door lock and specific power supply for access control should be purchased respectively Connect Keyp...

Page 6: ...six seconds RFID tags are all cleared after one beep admin code 9 Connect Electronic Door Lock To know connection steps please refer to the instruction manual of electronic door lock Installation Fix...

Page 7: ...rm press on the keypad the arm signal will be sent to the control panel after the set time Arm This setting does not apply to Stay Mode If both control panel and keypad are set delay time respectively...

Page 8: ...tup is successful Enable Speed SOS Dial Enter setup state input When one beep is heard and the LED indicator keeps on for 10 seconds the setup is successful Note Default setting 0 speed SOS dial is di...

Page 9: ...p is heard and the LED indicator keeps on for 10 seconds the setup is successful Disarming Silently by RFID Tag The control panel and siren will hoot twice when disarming by RFID tag If set disarming...

Page 10: ...m by RFID tag directly which is more convenient Enter setup state input When one beep is heard and the LED indicator keeps on for 10 seconds the setup is successful Note Default setting 0 turn on powe...

Page 11: ...te input When one beep is heard and the LED indicator keeps on for 10 seconds the setup is successful Note Admin code is 6 digits default code is 123456 Reset After reset the user code admin code and...

Page 12: ...s Using Keypad to Disarm Input user code or admin code and press key the LED indicator flashes once and the keypad beeps once and sends Disarm command to the control panel Disarm When the alarm panel...

Page 13: ...n the keypad is in Speed SOS Dial mode user just holds the key for 3 seconds the LED indicator flashes once the keypad beeps once and the control panel alarms immediately SOS When the keypad is not in...

Page 14: ...aving mode Please connect the RFID tag to control panel by following the manual instruction Enter setup state and activate the function of disarm by RFID tag Disarm after pressing key Keypad cannot be...

Page 15: ...l input for exit switch Technical Specifications Product Name Model No Power Supply Static Current Transmitting Current RFID Tags Supported Transmitting Distance Radio Frequency Housing Material Opera...

Reviews: