Installation and Setup
Mirage 4K25 Setup Guide
17
020-101362-02 Rev. 1 (01-2015)
6. Lock the feet in place by turning each lock nut until it fits tight against the projector.
Install the touch panel controller
1. Loosen the mounting arm just enough for the end to fit over the ball joint located on the rear
panel of the projector.
The touch panel controller (TPC) becomes loose from the mounting arm when the mounting
arm lock is loosened.
2. Tighten the mounting arm lock until it fits tightly on the joint.
The TPC safety strap comes installed on the projector ball point.
3. Connect the cable from the touch panel controller (TPC) to the connector on the rear panel of
the projector.
4. Adjust the TPC angle for optimal viewing, then tighten the mounting arm lock securely so that
the TPC is held in place at the required location.
Connect external exhaust ducting
Warning!
Failure to comply with the following could result in death or serious injury.
At minimum, a 10-inch (25.4 cm) long, strong metal duct must be installed at the projector
and installed to an outside venting duct system to prevent glass shards from exiting the duct
in the event of a lamp explosion.
Notice.
Failure to comply with the following may result in property damage.
*600 CFM is required in projection rooms with an ambient temperature above 25°C or
located at an elevation greater than 3000 feet above sea level.
19 mm
1
2
3