Operation
FHD552-X LCD Panel User Manual
33
020-000741-01 Rev. 1 (07-2014)
Image Settings
Use the controls in the Image Settings Menu to calibrate each display input to achieve optimum
picture quality.
Connect your test pattern source to the input that you are calibrating and proceed as follows.
Perform the adjustments in the order listed here.
Advanced
Settings
Auto Adjustment
No or Yes
Image Position (VGA mode)
Up, Down, Left, Right
Phase (VGA mode)
0, 1, 2 ... 63
Clocks (VGA mode)
0, 1, 2 ... 100
VGA ADC Settings
User ADC Calibration
Flesh Tone (Video Mode)
Off, Low, Medium or High
IRFM
Off or Standard or Video Wall
Baud Rate
115200, 38400, 19200 or 9600
Smart Light Control
Off or Local Dimming
Wake Up from Sleep
VGA Only, VGA, Digital, RS232 or
Never Sleep
Temperature & Fan Status
Temperature (
°C, °F)
Fan 1 Speed / Fan 2 Speed
Multi Display Control
Monitor ID
1, 2,3 ... 24, 25
Video Wall
Yes or No
DVI Indemnity
Yes or No
Power On Delay
0, 0.05, 0.10, 0.15, 0.20 ... 29.90,
29.95 or 30 sec.
Frame
Yes or No
Matrix X
1~10
Matrix Y
1~10
Division X
1~Matrix X
Division Y
1~Matrix Y
IR Mode
Off or Target or All
Recipient ID
1~100
Auto Video Wall Setup
Bottom-Left or Top-Left
Factory Reset
Yes or No
System
Status
Channel Information
Main
Active Source / Signal Resolution and
Refresh Rate
PIP
Total Hours
Firmware Version
Note: Default settings appear in bold type.