Service setups
HS Series 2K Service Manual—DWU1612-HS,DWU2022-HS
37
020-001790-01 Rev. 1 (03-2020)
Copyright ©2020 Christie Digital Systems USA Inc. All rights reserved.
• The IP address: 192.168.0.100 (default)
• The Subnet Mask: 255.255.255.0 (default)
2. In Network settings, set the projector IP address.
See
Performing a network function test on the network port
3. Read the projector information.
See
Performing a network function test on the network port
Performing a RS232 and video function test on
HDBaseT port
To perform the RS232 and video function test, complete the following steps.
1. Connect the CH-506TX, projector and PC as shown in step 5.
2. Switch the signal source to
HDBaseT
.
3. On the IR remote keypad, press the
Menu
button and select
Configuration
>
Communica-
tions
>
Serial port
>
HDBaseT
.
4. Set the PC Baud Rate to
115200
.
5. Input the RS232 command (SYS?).
The projector returns the following: (SYSx).
On-screen display functionality inspection
All on-screen display functions must be checked for functionality.
ID
Check item
Check point
1
General
When the on-screen display menu is displayed, no visible peaking, ringing,
streaking, or smearing artifacts are on the screen.
RJ45 to HDBaseT port
RS232 to PC
Power
HDMI input
Summary of Contents for DWU1612-HS
Page 1: ...HS Series 2K DWU1612 HS DWU2022 HS Service Manual 020 001790 01...
Page 107: ......