Service setups
HS Series 2K Service Manual—DWU1612-HS,DWU2022-HS
28
020-001790-01 Rev. 1 (03-2020)
Copyright ©2020 Christie Digital Systems USA Inc. All rights reserved.
Adjusting boresight
The boresight adjustment turns the lens holder to remove the tilt between the lens and DMD to
make the image clear, crisp, and sharp. To perform boresight adjustment, use an M4 Allen key to
adjust the three boresight set screws on the lens holder.
To perform boresight adjustment, complete the following steps:
1. Project a focus test pattern.
2. To optimize the focus of position 1 on the screen, press the
FOCUS
or
key.
3. Once position 1 is in focus, check position 2. If position 2 is not in focus, use the
FOCUS
or
key to bring position 2 into focus on the screen.
• If pressing the
FOCUS
key results in position 2 coming into focus, turn the set screw A
clockwise.
Items
Description
A, B, C
Boresight set screws
• To tighten the set screws, turn coun
t
erclockwise.
• To loosen the set screws, turn clockwise.
Christie recommends adjusting the set screws 1/4 turns each time. The balance between the set
screws is subtle and a small adjustment can make an obvious change on the screen.
B
C
A