MF1255C
Mechanical Switch Adjustment
procedure for Control Units
Refer to
Figure 55
.
A. Turn the adjustment nut counter-
clockwise until the switch clicks.
B. Turn the adjustment nut clockwise until
the switch clicks.
C. Turn the adjustment nut counter-
clockwise 3/4 turn.
SENSOR PLUS™ Sensor Switch Adjustment for Control Units
Refer to
Figure 56
.
The SENSOR PLUS™ Pan Half Round Sensor Switch is adjusted at the factory to a sensitivity of .125'' from the
face of the sensor and a time delay of 15 seconds, the time delay adjustment is 0 seconds to 600 seconds.
To adjust the Time Delay:
•
For less time — turn Time Delay Adjustment Screw counter-clockwise (Light blinks fast)
•
For more time — turn Time Delay Adjustment Screw clockwise (Light blinks slow)
Figure 56. Adjusting the SENSOR PLUS Proximity Switch
Feeder Line
Keep anti-roost cables tightly stretched. This increases the effectiveness of the electro-guard anti-roost system and
keep the pans from being tilted when birds push against them.
Remove all feed from the feeder when there are no birds in the house and when the building is washed and
disinfected.
Turn the feeders off prior to removing the birds from the house. This will allow them to clean the feed out of the
pans.
If the system is not to be used for an extended period of time, remove all the feed from the feeder lines and feeder
pans.
Disconnect power to the system to prevent accidentally starting the system.
1)
Adjustment Nut
1660-23 1/2001
Figure 55. Switch Adjustment
Adjustment Screw