Mid-Line Control
MODEL C2® Plus & MODEL G™ Plus Feeding System
30
MF1255C
Sensor Plus Switch:
a. Assemble the Mid-Line Control to the Feeder
Tube as shown in
Figure 47
.
b. Attach the Switch Box Assembly to the Feeder
Tube with Hose Clamps as shown in
Figure 47
.
4. Install a toggle switch, out of reach of the birds, to disconnect power to the Mid-Line Control. This
allows the Mid-Line Control to serve as standard feeder when not used as a control feeder.
5. Wire the Mid-Line Control as shown in the wiring diagram section of this manual.
1255-66 6/01
2529-711
42663 MODEL C2 PLUS
INTERMEDIATE CONTROL
WITH PROXIMITY SWITCH
CHORE-TIME EQUIPMENT
A DIVISION OF CTB INC.
MILFORD, INDIANA 46542-2000
Do not open this control
box until electrical power is
disconnected at circuit breakers.
ELECTROCUTION HAZARD!
DANGER
Figure 47. Installing the Sensor Plus Mid Line Control