Feeder Line Assembly and Suspension
MODEL C2® Plus & MODEL G™ Plus Feeding System
22
MF1255C
8. Install the Metal Water Tight Connector (item 1) in the Feed Line Motor (item 2). Cut the Flex Conduit (item
3) to length. Slide the wires from the end control through the Flex Conduit (item 3). Install the Flex Conduit
(item 3) in the connectors. Connect the wires to the Feed Line Motor (item 2).
Figure 32. Wiring the Motor
9. Attach all covers and wire according to the wiring section of this manual.
10. Pull the auger at the boot end until it begins stretching. Then let it relax. In the
relaxed
position,
mark the auger at the end of the boot. See
Figure 33
.
Figure 33. Measure the Auger from the relaxed position
11. Auger stretch:
The auger needs to be stretched 7"
[180 mm]
per 100’
[30 m]
. Example: A 300’
[90 m]
feeder line
requires 21"
[500 mm]
of stretch.
Beginning at the
relaxed
position, measure the required amount of stretch. Mark the auger at that
point.
Grip the auger 8"
[200 mm]
ahead of this mark with locking pliers. Allow the auger to pull back into
the boot so that the pliers rest against the end of the boot. See
Figure 34
.
2529-710
42680 MODEL C2 PLUS
END CONTROL
WITH PROXIMITY SWITCH
CHORE-TIME EQUIPMENT
A DIVISION OF CTB INC.
MILFORD, INDIANA 46542-2000
Do not open this control
box until electrical power is
disconnected at circuit breakers.
ELECTROCUTION HAZARD!
DANGER
1
2
3
4
10
11
5
6
9
1634-08 4/2000
7
8
1255-94 9/2000
1)
Mark the
relaxed
auger
at the end of the boot