ELECTRIC HOOK UP
To eliminate problems when the machine is commissioned, follow the instruction given below:
The electric hook up is customer's responsibility.
The machine must be connected to the electric mains using the cable supplied in the installation kit.
Voltage SINGLE-PHASE 230 V.ac +/- 1 0% or 1 1 5 V.ac +/- 1 0% . In this latter case, the voltage
change jumpers will have to be moved as shown in the figure.
Nominal frequency: .50 - 60 Hz
COMPRESSED AIR HOOK UP
The machine must be supplied with clean, dry compressed air delivered by a compressor capable
of providing at least 1 00 l/min of compressed air at 6 bar. The connecting point shown in the Figure
is a tapped ¼" gas fitting to which the required hose connector can be fitted. The inside diameter of
the air hose must be at least c 6 mm. Best not use a spiral hose. Best use rubberised canvas hoses
with a good thickness. The hoses should be subject to crimping or pinching.