INST.No.INE-454-P2 Software
Ver.1.2
-21-
[
Temperature display and
Number of analog output
correction data (number of
knee-point)]
[Temperature display and
Analog output correction
data No.]
4.10 Temperature display/Analog output correction programming
This mode is for the correction of temperature display and analog output by knee-points (up to 8
points).
It is necessary to program from 4.10.1 to 4.10.5 continuously.
4.10.1 Programming of number of temperature display
and analog output correction data (number of knee-point)
Program the number of the knee-point. When “
0
” is programmed, no temperature display and analog
output correction is executed.
4.10.2 Programming of temperature display and analog output correction data No.
Program the temperature display and the analog output correction data No, for the data to be
corrected.
Tb CONT MEM PEAK
AL
AH
C
F
ε
1) To program the number of temperature display and analog
output correction data, press SEL key in the engineering mode
screen until “
CP.n
” appears in the sub display as shown in the
right figure.
2) By pressing
key, the least significant digit of the main
display will blink.
3) Use
or
key to program the desired value.
4) To activate this programming, press
ENT
key.
Main display
Sub display
•
The numeric figure in the main display is available from
0
to
9
.
However, the programmable range is
0
and
2
to
8
.
•
The default value is
0
.
R e m a r k s
1) After the programming of the number of the temperature
display and the analog output correction data (number of
knee-point) in [4.10.1 Programming of number of
temperature display and analog output correction data
(number of knee-point)], press
SEL
key until “
no
”
(programming screen of temperature display and analog
output correction data No.) appears in the sub display
as
shown in the right figure.
2) By pressing
key, the least significant digit of the main
display will blink.
3) Use
or
key to program the desired value.
4) To activate this programming, press
ENT
key.
Tb CONT MEM PEAK
AL
AH
C
F
ε
Sub display
Main display
•
The numeric figure in the main display is available from
0
to
9
.
However, the programmable range is
1
to
8
.
•
The default value is
1
.
R e m a r k s
4. Engineering mode