![Chigo CCA-18HR1 Technical Manual Download Page 124](http://html1.mh-extra.com/html/chigo/cca-18hr1/cca-18hr1_technical-manual_2601241124.webp)
R410A50Hz Universal Outdoor Series Technical Manual Outdoor unit
121
GD Chigo Heating & Ventilation Equipment Co., Ltd.
Model
COU-36HSR1
COU-48HSR1
COU-60HSR1
Power supply type
Independent supply
Independent supply
Independent supply
Outdoor power supply
V/Ph/Hz
380~415/3/50
380~415/3/50
380~415/3/50
Cooling
Capacity
Btu/h
36000
48000
60000
KW
10.5
14
16
Input
W
3800
5000
5700
Rated current
A
6.79
8.94
10.19
Heating
Capacity
Btu/h
39600
52800
66000
KW
11.5
15.4
16.6
Input
W
3600
5100
5800
Rated current
A
6.44
9.12
10.37
Max. input consumption
W
4900
6000
6600
Max. current
A
8.76
10.73
11.8
Starting current
A
48
66
70
Compressor
Model
C-SBN303H8D
C-SBN373H8D
C-SBN453H8D
Type
SCROLL
SCROLL
SCROLL
Brand
SANYO
SANYO
SANYO
Capacity
Btu/h
36000
48100
56000
Input
W
3650
4750
5750
Rated current(RLA)
A
6.58
8.22
9.77
Locked rotor
Amp(LRA)
A
48
66
70
Thermal protector
built-in
built-in
built-in
Capacitor
μF
/
/
/
Refrigerant oil
ml
1700
1700
1700
Outdoor
motor fan
Model
YDK-200-6
YDK-60-6P3-1
YDK-60-6P3-1
Input
W
450
170×2
170×2
Capacitor
μF
10
4×2
4×2
Speed
r/min
800
780
780
Outdoor coil
Number of rows
1
2
2
Tube pitch x row
pitch
mm
25×21.65
22×19.05
25×21.65
Fin spacing
mm
1.4
1.6
1.6
Fin type
Hydrophilic
Hydrophilic
Hydrophilic
Tube outside dia.
and type
mm
9.52
7.94
9.52
inner grooved
inner grooved
inner grooved
Coil size(W×H×D)
mm
883.5×950×21.65
1735×1280×38.1
1804×1250×43.3
Number of circuits
3
7
7
Outdoor air flow
m
3
/h
6000
6100
6100
Outdoor noise level
dB(A)
55
57
57
Outdoor
unit
Dimension(W×H×D)
mm
1070×995×400
911×1335×400
911×1335×400
Packing(W×H×D)
mm
1145×1120×475
964×1445×402
964×1445×402
Net/Gross weight
kg
92/100
96/107
96/107
Refrigerant type/quantity
g
R410A/2100
R410A/3600
R410A/4000
Throttle part
capillary
capillary
capillary
Design pressure
MPa
4.2
4.2
4.2
Outdoor power supply
mm
2
1.5
2.5
2.5
Refrigeran
t piping
Liquid side/Gas side
mm
Φ9.52/Φ19.05
Φ9.52/Φ19.05
Φ9.52/Φ19.05
Max. pipe length
m
30
30
30
Max. high drop
m
20
20
20
Ambient temp
°C
-7
~
43
-7
~
43
-7
~
43
Stuffing Quantity
(
20'/40'/40'HQ
)
40/80/80
32/64/64
32/64/64
Notes: 1. Nominal cooling capacities are based on the following conditions:
Indoor temp: 27°CDB, 19°CWB; Outdoor temp: 35°CDB; Equivalent ref. Piping: 7.5m(horizontal)
2. Nominal heating capacities are based on the following conditions:
Indoor temp: 20°CDB; Outdoor temp: 7°CDB, 6°CWB; Equivalent ref. Piping: 7.5m(horizontal)