5.7.1
5.7.2
5.7.3
5.7.5
5.7.4
29
5.7 Completing an Operation and
Riveting Tool Storage
5.7.1
Always disconnect the compressed air sup-
ply from the pump after riveting and during
work interruptions.
5.7.2
Then disconnect the control hoses and seal
the openings.
Make sure that the disconnected hoses ne-
ver make contact with the dirty floor or the
ground.
5.7.3
Before and after each operation, check the
system for oil leaks. An oil leak indicates a
fault in the system. In such cases, disconti-
nue work and locate the fault or submit the
equipment for repair at an autho rized speci-
alist dealer.
Foreign bodies or contamination in the
hydraulic oil or in the control lines could
cause the equipment to malfunction.
5.7.4/5.7.5
Always store the tool in the transport
case designed for this purpose. Make
sure that the hoses do not become kin-
ked!
Never transport the tool by the hoses!