5.6.1
5.6.2
28
5.5 Checking Riveting Results
5.5.1
5.5.2
5.5.3
5.5.1 – 5.5.3
The results must be checked after the riveting opera-
tion. If the installed rivet does not meet quality requi-
rements, the reason for the fault must be determined.
If the quality of the installed rivet is acceptable, the
work process can be repeated.
After each riveting operation, check
that the rivet mandrel and rivet die are
firmly seated. If they have come loose,
they must be re-tightened using the
wrenches from the RIVKIT.
5.6.1
Remove adhesive residue from all contaminated tools
after each completed riveting operation.
5.6.2
To do this, remove all affected tool components and cle-
an using acetone or other solvents.
If adhesive residue is allowed to remain
on the riveting tool, it will eventually
cause a malfunction. Before starting
work, any rivet punches requiring re-
placement must be replaced with genu-
ine replacement parts.
5.6 Cleaning the Riveting Tools