8.4 POSITION OF INFORMATIVE LABELS FOR DRYER AND TANK
9.0 COMPRESSOR ROOM
9.1 FLOORING
The flooring must be level and of the industrial type, the overall machine weight is reported in Chap. 13.0. Keep the overall machine weight
in mind for its positioning.
9.2 VENTILATION
An appropriate choice of room will extend the service life of your compressor; the room must be large, dry, well-ventilated and not dusty.
The ambient temperature, with the machine running, must not exceed
46°C (104 °F)
and must not be less than
1°C (33.8 °F).
The room must have a volume of approximately
60 m
3.
The room must have 2 openings for ventilation, each having a
surface area of approximately
0.5 m
2
. The first opening must be positioned up high to allow the evacuation of hot air, the second opening
must be positioned down low to allow the intake of external ventilation air. In the case of dusty environments, it is recommended to install a
panel filter on these openings.
9.3 EXAMPLES OF COMPRESSOR ROOM VENTILATION
10.0 TRANSPORT & HANDLING
The machine must be transported as specified in the following figures.
11.0 UNPACKING
After having removed the packaging, inspect the integrity of the machine and check that there are no visibly damaged parts. In case of
doubt, do not use the machine and contact the manufacturer’s service centre or your retailer. Packing materials (plastic bags
) must not be
left within reach of children or dispersed in the environment insofar as they are potential sources of danger and pollution. Deposit such
materials in dedicated collection areas.