Instruction book
86
909935AIB
9.6 Settings of circuit breakers
Q25/26: supply of the motors of the air and oil cooling fans
CPF 300 A (CSA-UL, 60 Hz, SSCCR)
Compressor type
Supply voltage (V)
Setting (A)
CPF 300 A
460
7.4
9.7 Compressor data
Data for CPF 300 A 125 psi (8.6 bar) 60 Hz compressors
Specification (174)
Unit
CPF 300 A
Maximum working pressure
bar
9.1
Nominal working pressure
bar
8.6
Motor shaft speed
rpm
1790
Total electrical power input for air-cooled Pack
compressors (12)
kW
264
Mean sound pressure level for air-cooled Pack
compressors (18)
dB(A)
79
Oil capacity (approximately)
l
173
References
• (12) Supply voltage 400 V (for 50 Hz-units); 460 V (for 60 Hz-units). Data may differ 0.5%
maximum at other supply voltages < 1 kV and 3.5% maximum at supply voltages > 1 kV
• (18) A-weighted emission sound pressure level at the work station (LpWSAd). Measured
according to ISO 2151: 2004 using ISO 9614/2 (sound intensity method). A total correction
factor for uncertainties of 3 dB has to be added conform the test code. Possible noise from
discharge line, accessories and/or ancillary equipment is not included.
• (174) At reference conditions, unless otherwise stated and according to ISO 1217:2009
(fourth edition). Cooling medium temperature is always set to same value as air inlet
temperature.