Instruction book
909935AIB
71
Period
Running hours Operation
Yearly
--
Regrease motor; see section
for the grease type, interval and
quantity.
2-Yearly
8000
Have oil separator element replaced
When displayed --
Carry out service action according to the displayed service plans.
When operating in a dusty atmosphere, inspect the air filters more frequently.
Always use genuine filters.
The separator element must also be replaced when the pressure difference over the
element exceeds 0.8 bar (12 psi). Check the pressure drop when the compressor is
running loaded and preferably with a stable working pressure.
Damaged flexibles must be replaced immediately.
Service agreements
Chicago Pneumatic Customer Centers have a range of service agreements to suit your needs:
• An Inspection Plan
• A Preventive Maintenance Plan
• A Total Responsibility Plan
Contact your Customer Centre to set up a tailor-made service agreement. It will ensure optimum
operational efficiency, minimize downtime and reduce the total life cycle costs.
Service plan
A number of service operations are grouped (called Level A, Level B, Level C...). Each level
stands for a number of service actions to be carried out at the time intervals programmed in the
regulator.
When a level is reached, a message will appear on the screen. After carrying out all service
actions, the interval timers must be reset using the “Reset” key in the “Service” menu. Consult
your Service Centre.
6.2 Motors
Warning
Stop the compressor and switch off the voltage. The operator must apply all relevant
Never mix greases of different brands or types.
Fan motors
The bearings of the fan motors are greased for life. The fan motor must be replaced after 40000
operating hours.